Data for Diagnostic accuracy of a bovine specific electronic beta-hydroxybutyrate handheld meter in fresh blood and stored serum samples

Loading...
Thumbnail Image
Statistics
View Statistics

Collection period

2014-06-01
2014-09-01

Date completed

2014-09-01

Date updated

Time period coverage

Geographic coverage

Source information

Journal Title

Journal ISSN

Volume Title

Title

Data for Diagnostic accuracy of a bovine specific electronic beta-hydroxybutyrate handheld meter in fresh blood and stored serum samples

Published Date

2020-12-14

Author Contact

Rodriguez, Zelmar
zrodrigu@umn.edu

Type

Dataset
Observational Data

Abstract

This study aims to evaluate the diagnostic accuracy of the bovine specific beta-hydroxybutyrate (BHB) meter Nova Vet (NVET). We evaluated the accuracy and agreement of the NVET in fresh blood and thawed serum with the reference laboratory assay; and the repeatability, the interference by anticoagulants, and the optimum slope calibration factor. Results from the Precision Xtra (another already validated BHB meter) are also available.

Description

ketometers.csv: ID of cattle sampled, BHB concentration measurements using Nova Vet, Precision Xtra, laboratory assay, and Nova Vet in serum at five different slopes. repeatibility_NVet.csv: BHB concentration measured 20 times in 3 cows with the Nova Vet meter at two different days and using different batches of testing strips. repeatibility_PXtra.csv: BHB concentration measured 20 times in 3 cows with the Precision Xtra meter at two different days and using different batches of testing strips. interference.nv.csv: BHB concentration measured with Nova Vet meter using tubes containing both anticoagulants LI-HEP and K-EDTA20, and without anticoagulant. interference.px.csv: BHB concentration measured with Precision Xtra meter using tubes containing both anticoagulants LI-HEP and K-EDTA20, and without anticoagulant.

Referenced by

Rodriguez, Z., Caixeta, L. S., & Cramer, G. (2021). Diagnostic accuracy of a bovine specific electronic beta-hydroxybutyrate handheld meter in fresh blood and stored serum samples. Veterinary and Animal Science, 11, 100159.
https://doi.org/10.1016/j.vas.2020.100159

Related to

Replaces

item.page.isreplacedby

Publisher

Funding information

Minnesota Agricultural Experiment Station - Rapid Agricultural Response. NovaBiomedical.

item.page.sponsorshipfunderid

item.page.sponsorshipfundingagency

item.page.sponsorshipgrant

Previously Published Citation

Other identifiers

Suggested citation

Rodriguez, Zelmar; Caixeta, Luciano; Cramer, Gerard. (2020). Data for Diagnostic accuracy of a bovine specific electronic beta-hydroxybutyrate handheld meter in fresh blood and stored serum samples. Retrieved from the Data Repository for the University of Minnesota (DRUM), https://doi.org/10.13020/zn1k-5476.

Content distributed via the University Digital Conservancy may be subject to additional license and use restrictions applied by the depositor. By using these files, users agree to the Terms of Use. Materials in the UDC may contain content that is disturbing and/or harmful. For more information, please see our statement on harmful content in digital repositories.