Between Dec 19, 2024 and Jan 2, 2025, datasets can be submitted to DRUM but will not be processed until after the break. Staff will not be available to answer email during this period, and will not be able to provide DOIs until after Jan 2. If you are in need of a DOI during this period, consider Dryad or OpenICPSR. Submission responses to the UDC may also be delayed during this time.
 

Deterioration of Mixed Rebar and Fiber-Reinforced Concrete Bridge Decks

Loading...
Thumbnail Image

View/Download File

Persistent link to this item

Statistics
View Statistics

Journal Title

Journal ISSN

Volume Title

Title

Deterioration of Mixed Rebar and Fiber-Reinforced Concrete Bridge Decks

Published Date

2019-02

Publisher

Minnesota Department of Transportation

Type

Report

Abstract

Between 1973 and 1989, approximately 600 bridge decks were constructed in Minnesota with a top layer of epoxy-coated rebar and a bottom layer of uncoated rebar (i.e., mixed rebar deck) to potentially reduce corrosion in the top layer of rebar. In the last five years, at least 20 bridge decks were constructed with polypropylene fibers in the concrete mix to reduce the width and amount of cracking. This project investigated how mixed rebar or polypropylene fibers affected the rate of deterioration in bridge decks (e.g., spalling of underside of deck concrete or unsound concrete on the top wearing surface) compared to control structure decks of approximately the same age. Visual inspections were conducted on certain bridges to compare the visual degradation of the mixed rebar and fiber-reinforced decks with their control structure decks. The results were subdivided to indicate how the superstructure type, average daily traffic, route type, and wearing surface crack density affected the condition ratings and rate of deterioration. The mixed rebar decks reached worse condition states than the control structures when comparing the condition of the underside of the deck; steel superstructures had the largest negative affect on the deterioration. Recommendations included: create an inspection rating element for mixed rebar decks that quantifies the underside of deck crack density, use a robust crack sealing method on mixed rebar decks when they have been at NBE Element #12 CS2 for approximately 7 years, and continue comparing fiber-reinforced decks to control structure decks to analyze the deterioration over time.

Description

Related to

Replaces

License

Collections

Series/Report Number

;MnDOT 2019-09

Funding information

Isbn identifier

Doi identifier

Previously Published Citation

Other identifiers

Suggested citation

Treat, Corin; Dymond, Benjamin Z.. (2019). Deterioration of Mixed Rebar and Fiber-Reinforced Concrete Bridge Decks. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/203695.

Content distributed via the University Digital Conservancy may be subject to additional license and use restrictions applied by the depositor. By using these files, users agree to the Terms of Use. Materials in the UDC may contain content that is disturbing and/or harmful. For more information, please see our statement on harmful content in digital repositories.