Abstract

The goal of the project is to establish a non-destructive field testing technique, including a data analysis algorithm, for determining in-place pile lengths by way of seismic waves. The length of each pile supporting a high-mast light tower (HMLT) will be identified through a systematic sensing approach that includes (i) collection and classification of the pertinent foundation designs and soil conditions; (ii) use of ground vibration waveforms captured by a seismic cone penetrometer; (iii) three-dimensional visco-elastodynamic finite element analysis (FEA) used as a tool to relate the sensory data to in situ pile length; (iv) use of machine learning (ML) algorithms, trained with the outputs of FEA simulations, to solve the germane inverse problem; (v) HMLT field testing; and (vi) analysis-driven data interpretation. Several hundred HMLTs throughout Minnesota have foundation systems, typically concrete-filled steel pipe piles or steel H-piles, with no construction documentation (e.g., pile lengths). Reviews of designs within current standards suggest that some of these foundations may have insufficient uplift capacity in the event of peak wind loads. Without knowledge of the in situ pile length, an expensive retrofit or replacement program would need to be conducted. Thus, developing a screening tool to determine in situ pile length - as compared to a bulk retrofit of all towers with unknown foundations - would provide significant cost savings.

Description

Related to

Replaces

License

Collections

Series/Report Number

MnDOT;2022-28

Funding information

Isbn identifier

Doi identifier

Previously Published Citation

Other identifiers

Suggested citation

Kennedy, Daniel; Guzina, Bojan; Labuz, Joseph. (2022). Detecting Foundation Pile Length of High-Mast Light Towers. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/250146.

Content distributed via the University Digital Conservancy may be subject to additional license and use restrictions applied by the depositor. By using these files, users agree to the Terms of Use. Materials in the UDC may contain content that is disturbing and/or harmful. For more information, please see our statement on harmful content in digital repositories.