Between Dec 19, 2024 and Jan 2, 2025, datasets can be submitted to DRUM but will not be processed until after the break. Staff will not be available to answer email during this period, and will not be able to provide DOIs until after Jan 2. If you are in need of a DOI during this period, consider Dryad or OpenICPSR. Submission responses to the UDC may also be delayed during this time.
 

Weigh-in-Motion Sensor and Controller Operation and Performance Comparison

Loading...
Thumbnail Image

Persistent link to this item

Statistics
View Statistics

Journal Title

Journal ISSN

Volume Title

Title

Weigh-in-Motion Sensor and Controller Operation and Performance Comparison

Published Date

2018-01

Publisher

Minnesota Department of Transportation

Type

Report

Abstract

This research project utilized statistical inference and comparison techniques to compare the performance of different Weigh-in-Motion (WIM) sensors. First, we analyzed test-vehicle data to perform an accuracy check of the results reported by the sensor-vendor Intercomp. The results reported by Intercomp mostly matched with our own analysis, but the data were found to be insufficient to reach any conclusions about the accuracy of the sensor under different temperature and speed conditions. Second, based on the limited data from the Intercomp and IRD sensor systems, we performed tests of self-consistency and comparisons of measurements to inform the selection of a superior system. Intercomp sensor data were found to be not self-consistent but IRD data were. Given the different measurements provided by the two sensors, without additional data, we were not able to reach a conclusion regarding the relative accuracy or the duration of consistent observations before needing recalibration. Initial comparisons indicated potential problems with the Intercomp sensor. We then suggested alternate approaches that MNDOT could use to determine whether recalibration was required. Finally, we analyzed ten-month data from the IRD WIM system and four-month data from the Kistler WIM system to evaluate relative sensor accuracy. While both systems were found to be self-consistent within the data time frame, the Kistler system generated more errors than the IRD system. Conclusions regarding relative accuracy could not be reached without additional data. We identified the sorts of measurements that would need to be monitored for recalibration and the methodology needed for estimating future recalibration time.

Description

Related to

Replaces

License

Collections

Series/Report Number

MnDOT 2018-03;

Funding information

Isbn identifier

Doi identifier

Previously Published Citation

Other identifiers

Suggested citation

Gupta, Diwakar; Tang, Xiaoxu; Yuan, Lu. (2018). Weigh-in-Motion Sensor and Controller Operation and Performance Comparison. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/195172.

Content distributed via the University Digital Conservancy may be subject to additional license and use restrictions applied by the depositor. By using these files, users agree to the Terms of Use. Materials in the UDC may contain content that is disturbing and/or harmful. For more information, please see our statement on harmful content in digital repositories.