Between Dec 19, 2024 and Jan 2, 2025, datasets can be submitted to DRUM but will not be processed until after the break. Staff will not be available to answer email during this period, and will not be able to provide DOIs until after Jan 2. If you are in need of a DOI during this period, consider Dryad or OpenICPSR. Submission responses to the UDC may also be delayed during this time.
 

N95 filtering facepiece respirator fit test performance for the general population attending Minnesota State Fair 2021 and 2022

Loading...
Thumbnail Image
Statistics
View Statistics

Collection period

2021-08-26
2022-09-05

Date completed

Date updated

Time period coverage

Geographic coverage

Source information

Journal Title

Journal ISSN

Volume Title

Title

N95 filtering facepiece respirator fit test performance for the general population attending Minnesota State Fair 2021 and 2022

Published Date

2024-10-07

Author Contact

Arnold, Susan
arnol353@umn.edu

Type

Dataset
Field Study Data
Human Subjects Data

Abstract

This study aimed to investigate the performance of the general population passing quantitative fit tests for one type of N95 respirator (3M Aura Respirator 9205+) and consider the role of gender, age, race/ethnicity, and facial hair in the fit testing pass rate. The data was collected using a demographic questionnaire from the general population attending the Minnesota state fair 2021 and 2022. Demographic information included age (in years), gender, race/ethnicity, and facial hair (yes/no and type). Each participant also performed quantitative fit testing of N95 respirators (3M Aura Respirator 9205+) using a TSI PortaCount Pro+ model 8038. Fit testing was conducted according to the quantitative OSHA 29 CFR 1910.134 standard protocol with a criterion of ≥100 for pass level fit factor.

Description

Data contain N95 filtering facepiece respirator fit test performance.

Referenced by

N95 filtering facepiece respirator fit test performance for the general population by gender, age, race, and facial hair

Related to

Replaces

item.page.isreplacedby

Publisher

Funding information

item.page.sponsorshipfunderid

item.page.sponsorshipfundingagency

item.page.sponsorshipgrant

Previously Published Citation

Other identifiers

Suggested citation

Bagheri Hosseinabadi, Majid; Yu, Minji; Petersen, Ashley; Griffin, Linsey; Durfee, William; Arnold, Susan. (2024). N95 filtering facepiece respirator fit test performance for the general population attending Minnesota State Fair 2021 and 2022. Retrieved from the Data Repository for the University of Minnesota (DRUM), https://doi.org/10.13020/aw5t-0a47.

Content distributed via the University Digital Conservancy may be subject to additional license and use restrictions applied by the depositor. By using these files, users agree to the Terms of Use. Materials in the UDC may contain content that is disturbing and/or harmful. For more information, please see our statement on harmful content in digital repositories.