Vireo Flight 33

Title

Vireo Flight 33

Published Date

2017-10-05

Publisher

Type

Dataset

Abstract

Description

VIREO / Day16 / Flight33. TEST: Gather data for offline fault detection by injecting stuck surface fault with nominal controller. RESULT: Good flight, but detectability will be low unless changes in trajectory are performed. EVENTS: 1. Second flight wherein stuck surface faults are injected WITHOUT controller reconfiguration. The goal is to see what the nominal controller does when a fault is injected. The flight data will be useful for offline fault detection. 2. Aircraft switched into alpha mode (both surfaces operational) and it transitions to a left cirle at 250 ft AGL, 30 kts, 150 m radius. 3. The aircraft was then commanded to follow a box route. The sharp turns required to perform the box excited the controller and the stuck surface turned out to be problematic. To help the aircraft regain control, we needed to switch into alpha. This back and forth between alpha and bravo was repeated till the end of mission.

Related to

Replaces

License

Collections

Series/Report Number

Funding information

Isbn identifier

Doi identifier

Previously Published Citation

Suggested citation

Venkataraman, Raghu. (2017). Vireo Flight 33. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/198028.

Content distributed via the University Digital Conservancy may be subject to additional license and use restrictions applied by the depositor. By using these files, users agree to the Terms of Use. Materials in the UDC may contain content that is disturbing and/or harmful. For more information, please see our statement on harmful content in digital repositories.