Between Dec 19, 2024 and Jan 2, 2025, datasets can be submitted to DRUM but will not be processed until after the break. Staff will not be available to answer email during this period, and will not be able to provide DOIs until after Jan 2. If you are in need of a DOI during this period, consider Dryad or OpenICPSR. Submission responses to the UDC may also be delayed during this time.
 

Acoustic Emission Monitoring of a Fracture-Critical Bridge

Loading...
Thumbnail Image

View/Download File

Persistent link to this item

Statistics
View Statistics

Journal Title

Journal ISSN

Volume Title

Title

Acoustic Emission Monitoring of a Fracture-Critical Bridge

Published Date

2014-03

Publisher

Minnesota Department of Transportation Research Services & Library

Type

Report

Abstract

With bridge infrastructure in Minnesota aging, advancing techniques for ensuring bridge safety is a fundamental goal of the Minnesota Department of Transportation (MnDOT). As such, developing health monitoring systems for fracture-critical bridges is an essential objective in meeting the stated goal. This report documents the acquisition, testing and installation of a 16-sensor acoustic emission monitoring system in the Cedar Avenue Bridge, which is a fracture-critical tied arch bridge in Burnsville, Minnesota. The overall goal of the project was to demonstrate that acoustic emission technology could be used for global monitoring of fracture-critical steel bridges. Project activities included the acquisition of the monitoring equipment, its testing to verify compliance with manufacturer specifications, installation of the equipment on the selected bridge, field testing to calibrate the system, development of data processing protocols for the acoustic emission (AE) data, and the collection of field data for a period of 22 months. Fracture tests of notched cantilever steel beams were conducted in the laboratory to provide characterization data for fracture events.

Description

Related to

Replaces

License

Collections

Series/Report Number

MnDOT;2014-15

Funding information

University of Minnesota Department of Civil Engineering

Isbn identifier

Doi identifier

Previously Published Citation

Other identifiers

Suggested citation

Schultz, Arturo E.; Morton, Daniel L.; Tillmann, Anton S.; Campos, Javier E.; Thompson, David J.; Lee-Norris, Alexandria J.; Ballard, Ryan M.. (2014). Acoustic Emission Monitoring of a Fracture-Critical Bridge. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/163209.

Content distributed via the University Digital Conservancy may be subject to additional license and use restrictions applied by the depositor. By using these files, users agree to the Terms of Use. Materials in the UDC may contain content that is disturbing and/or harmful. For more information, please see our statement on harmful content in digital repositories.