Tests Of The Woolley Valve For The James H. Campbell Plant, Unit No. 3

Loading...
Thumbnail Image

View/Download File

Persistent link to this item

Statistics
View Statistics

Journal Title

Journal ISSN

Volume Title

Title

Tests Of The Woolley Valve For The James H. Campbell Plant, Unit No. 3

Published Date

1979-11

Publisher

St. Anthony Falls Laboratory

Type

Report

Abstract

The innovative use of fixed screens to reject solids in condenser cooling water drawn from Lake Michigan has been considered a practical solution for the lake withdrawal system proposed at the James H. Campbell, Unit No.3 Of the Consumer Power Company. The withdrawal point, which is 3,500 feet offshore and approximately 30 feet below the lake surface, is considered relatively free of screen-plugging.solids under normal conditions, but during winter, frazil ice plugging is possible. To assure continued operation under these unusual conditions it was considered necessary to provide the system with an opened water (non-screened) auxiliary intake. This auxiliary function is to be provided by installing a relief valve at the outer or stub end of two of the four header pipes which are to constitu.te the intake system as shown in Fig. 1. These valves are to open and provide .auxiliary intake water whenever screen plugging resulted in a selected level of pressure reduction within the header. The selected level proposed for the valve operation was 12 inches additional headloss. The valve deemed most appropriate for use was a modified version of a Synchro-chek valve made by the W. J. Woolley Company of River Forest, Illinois. The Woolley valve has been marketed for many years as a pump discharge check valve, but its performance under Wave conditions, including 100 year storms, at the proposed site were unknown. In order to clarify the valve .performance it was decided to conduct tests of a 1:4 scale-model valve at the St. Anthony Falls Hydraulic Laboratory of the University of Minnesota. The material which follows describes the Woolley valve, the three part test program (static, steady state flow, and dynamic flow), the test facilities, the test results, and the conclusions and recommendations resulting from the tests.

Keywords

Description

Related to

Replaces

License

Collections

Funding information

Consumer Power Company; Commonwealth Associates Inc

Isbn identifier

Doi identifier

Previously Published Citation

Suggested citation

Ripken, John F.; Dahlin, Warren Q.; Wood, Addison O.; Ferguson, Jeffrey E.. (1979). Tests Of The Woolley Valve For The James H. Campbell Plant, Unit No. 3. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/118562.

Content distributed via the University Digital Conservancy may be subject to additional license and use restrictions applied by the depositor. By using these files, users agree to the Terms of Use. Materials in the UDC may contain content that is disturbing and/or harmful. For more information, please see our statement on harmful content in digital repositories.