Title
Experimental Flow Studies With the Dual-Screen Cooling Water Intake Assembly ("Riser") for the James H. Campbell Electric Power Generating Plant, Unit No. 3
Published Date
1978-12
Publisher
St. Anthony Falls Laboratory
Type
Report
Abstract
Flow characteristics inside and outside of a dual-screen cooling
water intake assembly ("riser") for the James H. Campbell Unit No.3
were observed and measured in hydraulic models at scales of 1:3 and 1:12.
Risers consist of dual cylindrical screens with horizontal axis and solid
endplates mounted on a T-assembly which is supported by a 3.5 ft diameter
vertical withdrawal pipe. Pressure losses within the assembly, approach
flow velocity patterns and approach flow velocities on the screen surface
were investigated. A total headloss coefficient of 4.6 resulting in an
equivalent full-scale headloss of 8.0" of water at a withdrawal rate of
29.44 ofs through the assembly was measured in the model. Flow patterns
towards single and multiple risers were observed by dye tracing techniques.
Approach flow velocities were measured on the surface of the 1: 3 scale
riser model. The highest velocities were found near the center of the
screen and the lowest ones near the projecting endplates. Maximum local
velocities exceeded calculated average velocity by about 30 per cent.
Keywords
Description
Related to
Replaces
License
Collections
Series/Report Number
St. Anthony Falls Laboratory Project Reports
177
177
Funding information
Consumer Power Company; Commonwealth Associates Inc
Isbn identifier
Doi identifier
Previously Published Citation
Other identifiers
Suggested citation
Stefan, Heinz G.; Dahlin, Warren Q.; Ripken, John F.; Wood, Addison; Winterstein, Tom. (1978). Experimental Flow Studies With the Dual-Screen Cooling Water Intake Assembly ("Riser") for the James H. Campbell Electric Power Generating Plant, Unit No. 3. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/118560.
Content distributed via the University Digital Conservancy may be subject to additional license and use restrictions applied by the depositor. By using these files, users agree to the Terms of Use. Materials in the UDC may contain content that is disturbing and/or harmful. For more information, please see our statement on harmful content in digital repositories.