Experimental Flow Studies With the Dual-Screen Cooling Water Intake Assembly ("Riser") for the James H. Campbell Electric Power Generating Plant, Unit No. 3

Loading...
Thumbnail Image

View/Download File

Persistent link to this item

Statistics
View Statistics

Journal Title

Journal ISSN

Volume Title

Title

Experimental Flow Studies With the Dual-Screen Cooling Water Intake Assembly ("Riser") for the James H. Campbell Electric Power Generating Plant, Unit No. 3

Published Date

1978-12

Publisher

St. Anthony Falls Laboratory

Type

Report

Abstract

Flow characteristics inside and outside of a dual-screen cooling water intake assembly ("riser") for the James H. Campbell Unit No.3 were observed and measured in hydraulic models at scales of 1:3 and 1:12. Risers consist of dual cylindrical screens with horizontal axis and solid endplates mounted on a T-assembly which is supported by a 3.5 ft diameter vertical withdrawal pipe. Pressure losses within the assembly, approach flow velocity patterns and approach flow velocities on the screen surface were investigated. A total headloss coefficient of 4.6 resulting in an equivalent full-scale headloss of 8.0" of water at a withdrawal rate of 29.44 ofs through the assembly was measured in the model. Flow patterns towards single and multiple risers were observed by dye tracing techniques. Approach flow velocities were measured on the surface of the 1: 3 scale riser model. The highest velocities were found near the center of the screen and the lowest ones near the projecting endplates. Maximum local velocities exceeded calculated average velocity by about 30 per cent.

Keywords

Description

Related to

Replaces

License

Collections

Series/Report Number

St. Anthony Falls Laboratory Project Reports
177

Funding information

Consumer Power Company; Commonwealth Associates Inc

Isbn identifier

Doi identifier

Previously Published Citation

Other identifiers

Suggested citation

Stefan, Heinz G.; Dahlin, Warren Q.; Ripken, John F.; Wood, Addison; Winterstein, Tom. (1978). Experimental Flow Studies With the Dual-Screen Cooling Water Intake Assembly ("Riser") for the James H. Campbell Electric Power Generating Plant, Unit No. 3. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/118560.

Content distributed via the University Digital Conservancy may be subject to additional license and use restrictions applied by the depositor. By using these files, users agree to the Terms of Use. Materials in the UDC may contain content that is disturbing and/or harmful. For more information, please see our statement on harmful content in digital repositories.