Energy Efficiency Comparison Study of Concrete Block Structures
Loading...
View/Download File
Persistent link to this item
Statistics
View StatisticsJournal Title
Journal ISSN
Volume Title
Title
Energy Efficiency Comparison Study of Concrete Block Structures
Alternative title
Natural Resources Research Institute Technical Report
Authors
Published Date
1991-07
Publisher
University of Minnesota Duluth
Type
Technical Report
Abstract
The Natural Resources Research Institute (NRRI), with a grant from the Minnesota
Department of Administration, has evaluated the energy saving potential of an insulated concrete
block product manufactured by Sparfil International, Inc. The blocks used in the study
contained taconite tailings (Sparfil-Tac) in place of sand.
A comparative evaluation of two 400 ft2 test buildings, identical in all respects except
for wall construction (conventional 12-inch concrete block versus 12-inch Sparfil-Tac insulated
block), shows the Sparfil-Tac product to have superior thennal insulating properties. Both
buildings were heated electrically. The Sparfil-Tac test building consumed 44.6% less electricity
than its conventional concrete block counterpart over a six-month test period (December 26,
1989, through June 27, 1990). This energy consumption differential, while significant, was less
than expected. A 65 .4 % reduction in energy consumption should have been realized, based on
heat loss calculations for all test building components. A guarded hot box test (ASTM C-236)
perfonned by Twin City Testing Corporation showed the Sparfil-Tac product to have a thennal
resistance (R-value) of 10.02 rather than the expected 24.5. This lower R-value is supported
by the heat loss calculations which show the Sparfil-Tac test building to have an R-value of 8.45.
To determine if the lower R-value was due to faulty block fabrication or some other factor, an
additional guarded hot box test was performed on Sparfil's regular (non-taconite tailings) block.
The second test showed these blocks to have an R-value of 10.80 rather than the R-value of 24.5
claimed in Sparfil product brochures. The R-value discrepancy is most likely due to the
improper application of heat flow concepts by Sparfil International when calculating thermal
resistances for their block products. This is particularly true for blocks whose hollow cores are
filled with expanded polystyrene (EPS) inserts. The two guarded hot box tests show that the
EPS inserts do not increase the insulating value of the blocks to the extent claimed.
The economics of each building type were compared by using the difference in energy
consumption between the two buildings. Based on quoted power and construction costs, a
payback period ranging from 3.6 to 10.1 years was calculated for the 400 ft2 Sparfil-Tac
product; had the block performed as expected, the payback period would have, instead, ranged
from 2.5 to 7 years. The variable payback period reflects the range of construction costs used
in the economic analysis. Economies of scale show the Sparfil-Tac product is more costcompetitive
in larger building applications.
Additional guarded hot box thermal testing of regular Sparfil blocks is recommended
given the difference between the actual (test-based) and claimed (calculation-based) R-values.
Calculated (in effect, idealized) values should only be relied on when they are supported by
experimental results. Based on this additional testing, further economic analyses could then be
performed.
Based on the results of the study described in this report, Sparfil-Tac blocks are superior
to regular concrete blocks in terms of R-value achieved per square foot of construction cost
($/ft2 + R-value). When construction does not require concrete blocks, other construction
techniques will yield a considerably smaller ratio ($/ft2 + R-value), thus more insulating for the
construction dollars spent.
Description
Related to
Replaces
License
Collections
Series/Report Number
NRRI Technical Report;NRRI/TR-91/03
Funding information
University of Minnesota Duluth, Natural Resources Research Institute, 5013 Miller Trunk Highway, Duluth, MN 55811-1442; Funded by the Minnesota Department of Administration
Isbn identifier
Doi identifier
Previously Published Citation
Other identifiers
Suggested citation
Zanko, Lawrence M; Johnson, T. B. (1991). Energy Efficiency Comparison Study of Concrete Block Structures. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/188350.
Content distributed via the University Digital Conservancy may be subject to additional license and use restrictions applied by the depositor. By using these files, users agree to the Terms of Use. Materials in the UDC may contain content that is disturbing and/or harmful. For more information, please see our statement on harmful content in digital repositories.