Between Dec 19, 2024 and Jan 2, 2025, datasets can be submitted to DRUM but will not be processed until after the break. Staff will not be available to answer email during this period, and will not be able to provide DOIs until after Jan 2. If you are in need of a DOI during this period, consider Dryad or OpenICPSR. Submission responses to the UDC may also be delayed during this time.
 

Novel Artificial Urinary Sphincter for Stress Urinary Incontinence Treatment

Loading...
Thumbnail Image

Persistent link to this item

Statistics
View Statistics

Journal Title

Journal ISSN

Volume Title

Title

Novel Artificial Urinary Sphincter for Stress Urinary Incontinence Treatment

Published Date

2017-09

Publisher

Type

Thesis or Dissertation

Abstract

The American Medical System’s AMS 800TM has been the gold standard for over 40 years with over 150,000 patients treated for Urinary Incontinence and is the leading treatment for male stress urinary incontinence (SUI) following prostate surgery. Type III SUI, or intrinsic sphincter deficiency, is the inability of the urethra to maintain closure pressure sufficient to keep the patient clinically dry at rest and during periods of heightened activity (~120 cmH2O; coughs, sneezes, posture changes, and exercises). The current AMS 800TM is not personalized to a patient’s needs and compromises with an in between pressure- as high (61-70 cmH2O) as it can be without exceeding safety threshold levels. As such many men still leak when they are active. The market is hungry for a device that can adapt to the patient’s level of activity, reducing pressure most of the day to protect the urethra and then briefly increasing the pressure when he is more active. We are developing a novel implantable pump (henceforth called “add-on device”) which will be an add-on to the AMS 800TM and it includes a solenoid coil-cum-plunger and a fluid reservoir within the pump body. The add-on device will be small, light-weight and battery powered, and maintain compatibility with the AMS 800TM device. The device idea is in its proof-of-concept stage. This add-on device can be a possible solution to reducing the risks including urethral atrophy (leading to return of incontinence) and erosion (leading to infection of the implant) resulting from the constant pressure.

Description

University of Minnesota M.S.E.E. thesis. September 2017. Major: Electrical Engineering. Advisor: Gerald Timm. 1 computer file (PDF); xiv, 129 pages.

Related to

Replaces

License

Series/Report Number

Funding information

Isbn identifier

Doi identifier

Previously Published Citation

Other identifiers

Suggested citation

Mishra, Avishek. (2017). Novel Artificial Urinary Sphincter for Stress Urinary Incontinence Treatment. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/198955.

Content distributed via the University Digital Conservancy may be subject to additional license and use restrictions applied by the depositor. By using these files, users agree to the Terms of Use. Materials in the UDC may contain content that is disturbing and/or harmful. For more information, please see our statement on harmful content in digital repositories.