Comparison of the Dimensional Stability of Splinting Material with Different Polymerization Times

Loading...
Thumbnail Image

Persistent link to this item

Statistics
View Statistics

Journal Title

Journal ISSN

Volume Title

Title

Comparison of the Dimensional Stability of Splinting Material with Different Polymerization Times

Published Date

2016-05

Publisher

Type

Thesis or Dissertation

Abstract

Purpose: The purpose of this study was to evaluate the effects of polymerization time and sectioning on the dimensional changes of auto-polymerizing acrylic resin used in splinting impression copings and the resulting fit of the prosthesis. Materials and Methods: Open-tray impression copings were connected to a master cast containing 5 external-hex implants. Auto-polymerizing acrylic resin was allowed to polymerize in a heavy-body polyvinyl siloxane matrix according to 3 different time groups (8 minutes (8MN), 1 hour (1HR), and 24 hours (24HR)), with 20 sets of splinted impression copings per time group. Each time group was further divided into non- sectioned (NS) and sectioned (S) groups (10 samples per group). A total of 60 gypsum bases were fabricated from implant analogs connected to the impression copings. A milled titanium bar fabricated from the master cast was used to verify the fit of the bar to the implant analogs. The casts were viewed using loupes (2.5x magnification) and a microscope (12.8x magnification) to visually detect any gap. The gap sizes were evaluated with a measuring gauge with pre-determined thickness in microns (μm). Results: Of the 30 casts tested in the sectioned groups (8MN-S, 1HR-S, and 24HR-S), all of the casts displayed clinical fit when evaluated with magnification loupes and a dental explorer. From this evaluation, only the 8MN-S group showed statistical significant difference (p < 0.05) when compared to its non-sectioned counterpart (8MN- NS). When evaluated with a microscope, no significant differences were found between the different time groups or sectioned samples. The microscope was able to detect gaps that were not detectable with magnification loupes and a dental explorer. Conclusion: Overall, difference in polymerization time and sectioning did not have an effect on the accuracy of fit. Sectioning for the 8-minute time group did show an improvement in the fit when compared to the non-sectioned samples. Although clinical fit appeared to be present, it did not always indicate the presence of absolute fit.

Description

University of Minnesota M.S. thesis. May 2016. Major: Dentistry. Advisor: Heather Conrad. 1 computer file (PDF); vii, 71 pages.

Related to

Replaces

License

Series/Report Number

Funding information

Isbn identifier

Doi identifier

Previously Published Citation

Other identifiers

Suggested citation

Kiangsoontra, Jason. (2016). Comparison of the Dimensional Stability of Splinting Material with Different Polymerization Times. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/182110.

Content distributed via the University Digital Conservancy may be subject to additional license and use restrictions applied by the depositor. By using these files, users agree to the Terms of Use. Materials in the UDC may contain content that is disturbing and/or harmful. For more information, please see our statement on harmful content in digital repositories.