Between Dec 19, 2024 and Jan 2, 2025, datasets can be submitted to DRUM but will not be processed until after the break. Staff will not be available to answer email during this period, and will not be able to provide DOIs until after Jan 2. If you are in need of a DOI during this period, consider Dryad or OpenICPSR. Submission responses to the UDC may also be delayed during this time.
 

Low Background Measurements of Radioisotope Contamination via Gamma Spectroscopy

2012-04-18
Loading...
Thumbnail Image

View/Download File

Persistent link to this item

Statistics
View Statistics

Journal Title

Journal ISSN

Volume Title

Title

Low Background Measurements of Radioisotope Contamination via Gamma Spectroscopy

Published Date

2012-04-18

Publisher

Type

Presentation

Abstract

Astronomical observations have shown that most of the universe is made up of dark matter and dark energy rather than the normal matter and energy we observe every day. The Cryogenic Dark Matter Search, CDMS, is working to detect dark matter particles with very pure, super-cooled germanium crystals. In order to be sensitive enough to discover weakly interacting dark matter the germanium detectors must be well shielded by placing them deep underground and surrounding them with lead in addition to many other means. In this research project the low level contamination of materials used in the construction of current and planned detector assemblies was measured in order to reduce the background of future CDMS detectors. The isotopes investigated included U-238, Th-232, K-40, Co-60 and Cs-137. The contamination measurements were done via gamma spectroscopy in a low background detector, named Gopher, located in the Soudan mine. A selection of the analyzed samples are presented here, as well as the results of a shielding upgrade to Gopher that improved its measurement capabilities considerably. The results obtained in Gopher are very important to improving the CDMS experiment in the future and it's new shield design can be used in upgrading similar detectors elsewhere.

Description

Mentor: Priscilla Cushman

Related to

Replaces

License

Series/Report Number

Funding information

This research was supported by the Undergraduate Research Opportunities Program (UROP).

Isbn identifier

Doi identifier

Previously Published Citation

Other identifiers

Suggested citation

Epland, Matthew. (2012). Low Background Measurements of Radioisotope Contamination via Gamma Spectroscopy. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/123282.

Content distributed via the University Digital Conservancy may be subject to additional license and use restrictions applied by the depositor. By using these files, users agree to the Terms of Use. Materials in the UDC may contain content that is disturbing and/or harmful. For more information, please see our statement on harmful content in digital repositories.