Miniaturizable Ion-Selective Electrode System: Solid Contact Electrode and Liquid Junction Free Reference Electrode

2014-05
Loading...
Thumbnail Image

Persistent link to this item

Statistics
View Statistics

Journal Title

Journal ISSN

Volume Title

Title

Miniaturizable Ion-Selective Electrode System: Solid Contact Electrode and Liquid Junction Free Reference Electrode

Authors

Published Date

2014-05

Publisher

Type

Thesis or Dissertation

Abstract

Ion-selective electrodes (ISEs) are widely used as important, analytical tools to determine the concentration of a broad range of ions for clinical analysis. As a potentiometric sensor, an ISE is comprised of two major parts: an ion-selective electrode and a reference electrode, both of which are vital in guaranteeing accurate and reliable measurement results. Conventional ISEs have an interior solution that forms a liquid contact with a selective membrane. However, complications due to evaporation and freezing in certain circumstances lead to irreproducibility, instability of the signals, and shortened life expectancy. In addition, miniaturization is an obstacle for this type of electrode. A universal method for a solid contact electrode that is calibration-free, durable, reproducible, and inexpensive to fabricate. A plasticized poly(vinylchloride) doped with tris(1,10-phenanthroline) cobalt(2+) tetrakispentafluorophenylborate and tris(1,10-phenanthroline) cobalt(3+) tetrakispentafluorophenylborate has been developed as a transducer layer. This layer has shown very reproducible potential in potassium chloride solutions with a potentil of standard deviation of 0.5 mV and response slope of 61mV / decade to varying concentrations. A redox buffer platform, based on the more lipophilic redox buffer consisting of the Co(III) and Co(II) complexes of 4,4'-dinonyl-2,2'-bipyridyl, was developed and applied to K<super>+</super>, Na<super>+</super>, Ca<super>2+</super>, H<super>+</super>, and CO<sub>3</sub><super>2-</super> with emf values of an electrode-to-electrode standard deviation as low as 0.7 mV (2% error in concentration) The reference electrode must maintain a constant potential over long periods of continuous measurements. Used in real life samples, salt bridges for conventional reference electrodes clog with proteins and lipids, suffer from contamination by sample components. A new method was developed that involves the application of a current pulse to a hydrophobic ion-doped membrane, thereby controlling transmembrane ion fluxes to obtain a sample independent reference electrode potential. The concentration of the ions released into the sample depended on the current amplitude and length and can be explained quantitatively by diffusion theory. The observable stability of the potential exhibited in this study by reference electrodes exposed to serum was particularly promising in view of biological and medical applications that require long term monitoring.

Description

University of Minnesota Ph.D. dissertation. May 2014. Major: Chemistry. Advisor: Philippe Buhlmann. 1 computer file (PDF); xxii, 181 pages.

Related to

Replaces

License

Collections

Series/Report Number

Funding information

Isbn identifier

Doi identifier

Previously Published Citation

Other identifiers

Suggested citation

Zou, Xu. (2014). Miniaturizable Ion-Selective Electrode System: Solid Contact Electrode and Liquid Junction Free Reference Electrode. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/181695.

Content distributed via the University Digital Conservancy may be subject to additional license and use restrictions applied by the depositor. By using these files, users agree to the Terms of Use. Materials in the UDC may contain content that is disturbing and/or harmful. For more information, please see our statement on harmful content in digital repositories.