Abstract
This report covers feasibility study of the possibility of using
the cavitation performance of standard bodies to measure the strength of water. An analytical cavitation model which utilizes a series of mathematically derived axisymmetric test bodies is combined with an acoustical cavitation occurrence counting instrumentation technique to establish an
index which indicates the cavitation susceptibility of the test water in water tunnels. An equivalent size distribution of entrained microbubbles is proposed to represent the actual stream nuclei and to serve as the cavitation susceptibility index.
Keywords
Description
Related to
Replaces
License
Collections
Series/Report Number
St. Anthony Falls Laboratory Project Reports
118
118
Funding information
Naval Ship Research and Development Center, Bethesda, Maryland 20034
Isbn identifier
Doi identifier
Previously Published Citation
Other identifiers
Suggested citation
Schiebe, Frank R.. (1972). Measurement of the Cavitation Susceptibility of Water Using Standard Bodies. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/108338.
Content distributed via the University Digital Conservancy may be subject to additional license and use restrictions applied by the depositor. By using these files, users agree to the Terms of Use. Materials in the UDC may contain content that is disturbing and/or harmful. For more information, please see our statement on harmful content in digital repositories.