Garment-Based Respiration And Pulse Oximetry Sensing Using A Stitched Sensor And Chest Mounted Pulse Oximetry Sensor

Loading...
Thumbnail Image

Persistent link to this item

Statistics
View Statistics

Journal Title

Journal ISSN

Volume Title

Title

Garment-Based Respiration And Pulse Oximetry Sensing Using A Stitched Sensor And Chest Mounted Pulse Oximetry Sensor

Published Date

2023-08

Publisher

Type

Thesis or Dissertation

Abstract

Garment-based wearable devices have the potential to make on-body sensing of vital signs a more seamless part of everyday life. This research seeks to investigate a wearable chest-mounted stitched strain sensor and pulse oximeter for the purpose of developing a garment-based sensing device. A wearable or garment-based device could be used for long term or long distance monitoring a wearer’s respiratory health when regular access to healthcare is challenging due to distance, such as is the case in many rural communities. However, the effect of fit and sizing of a wearable device is a significant challenge when it comes to the balancing comfort and sensor accuracy needs in a wearable device. A stitched conductive thread sensor and an adapted pulse oximeter probe integrated into a chest-mounted mounted adjustable sensor belt were investigated to understand their performance relative to more typical sensing approaches. Two fit conditions were employed to measure effects on sensor performance and understand the challenges presented by garment-based sensing of respiratory signals. This research found that in general a tighter fit condition improved the performance of the stitched respiration sensor and chest mounted pulse oximeter, however sensor dropout greatly influenced both blood oxygen saturation (SpO₂) and beats-per-minute (BPM) data resulting in suboptimal readings. The stitched sensor was more accurate in measuring breath frequency than the comparison clinical device when fit was not optimized. As a result of this research, it is clear that the fit and sizing of a garment-based sensing device is a crucial factor in developing sensing garments suitable for everyday use.

Description

University of Minnesota M.S. thesis. August 2023. Major: Design, Housing and Apparel. Advisor: Lucy Dunne. 1 computer file (PDF); vii, 86 pages.

Related to

Replaces

License

Series/Report Number

Funding information

Isbn identifier

Doi identifier

Previously Published Citation

Other identifiers

Suggested citation

Clarke, Megan. (2023). Garment-Based Respiration And Pulse Oximetry Sensing Using A Stitched Sensor And Chest Mounted Pulse Oximetry Sensor. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/258854.

Content distributed via the University Digital Conservancy may be subject to additional license and use restrictions applied by the depositor. By using these files, users agree to the Terms of Use. Materials in the UDC may contain content that is disturbing and/or harmful. For more information, please see our statement on harmful content in digital repositories.