Abstract
The St. Anthony Falls Hydraulic Laboratory (SAFHL) performed field
flow measurement tests for six large Venturi meters (MI00A, MI00B,
MI0IA, MI0IB, MI02A, MI02B) owned and operated by the Metropolitan
Waste Control Commission (MWCC), and installed in the 1930's. The
MWCC oversees the collection and treatment of sanitary wastewater
discharges in the Twin Cities Metropolitan area of Minnesota. The tests
were completed as a subcontract to James M. Montgomery Consulting
Engineers, Inc. (JMM), of Wayzata, Minnesota, with whom the MWCC had
contracted to conduct an overall evaluation of the Venturi meters.
Four of the six Venturi meters (Fig. 1) were located on the west bank
of the Mississippi River, just upstream from the Lake Street bridge; two of
these meters had throat diameters of 42 inches, with the other two having
throat diameters of 25 inches. The two remaining meters (Fig. 2), each
with a throat diameter of 25 inches, were located at the Minneapolis-St.
Paul border, along the east bank of the Mississippi River.
Keywords
Description
Related to
Replaces
License
Collections
Series/Report Number
Project Reports
312
312
Funding information
James M. Montgomery Consulting Engineers, Inc.; The Metropolitan Waste Control Commission
Isbn identifier
Doi identifier
Previously Published Citation
Other identifiers
Suggested citation
Voigt, Richard L.; Bauers, Curtis W.. (1991). Field Flow Testing of Six Large Venturi Meters. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/108533.
Content distributed via the University Digital Conservancy may be subject to additional license and use restrictions applied by the depositor. By using these files, users agree to the Terms of Use. Materials in the UDC may contain content that is disturbing and/or harmful. For more information, please see our statement on harmful content in digital repositories.