Vireo Flight 20

Title

Vireo Flight 20

Published Date

2017-08-23

Publisher

Type

Dataset

Abstract

Description

VIREO / Day11 / Flight20. TEST: Closed-loop control law validation. RESULT: Good flight for control law validation. EVENTS: 1. Turned off all longitudinal control loops except total energy to throttle. Elevator was held fixed at -5 deg TE up. 2. Under the degraded conditions, the altitude tracker was assisted by an airspeed damper and an airspeed filter. The BW of the airspeed filter was 1 Hz, thus ensuring that the high frequency noise in the airspeed measurements are not propagated down to the throttle command. 3. The addition of airspeed damper and filter to the altitude tracker was beneficial in keeping the airspeed from diverging. However, the performance was still not as good as TECS. 4. We completed the autoland.

Related to

Replaces

License

Collections

Series/Report Number

Funding information

Isbn identifier

Doi identifier

Previously Published Citation

Other identifiers

Suggested citation

Venkataraman, Raghu. (2017). Vireo Flight 20. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/198014.

Content distributed via the University Digital Conservancy may be subject to additional license and use restrictions applied by the depositor. By using these files, users agree to the Terms of Use. Materials in the UDC may contain content that is disturbing and/or harmful. For more information, please see our statement on harmful content in digital repositories.