Tensile and Shear Capacity of Post-Installed GFRP Bars in Concrete

Loading...
Thumbnail Image

Persistent link to this item

Statistics
View Statistics

Journal Title

Journal ISSN

Volume Title

Title

Tensile and Shear Capacity of Post-Installed GFRP Bars in Concrete

Alternative title

Published Date

2021-12

Publisher

Type

Thesis or Dissertation

Abstract

Post-installed reinforcing bars are frequently used to connect new concrete members to an existing structure. In these applications, uncoated steel reinforcing bars are often used, which are susceptible to corrosion. The use of glass fiber-reinforced polymer (GFRP) reinforcing bars in structural concrete has increased in recent years due to many factors, including their noncorrosive and nonconductive nature, high tensile strength, and nonmagnetic properties. Currently, structural concrete design using GFRP reinforcing bars is covered in ACI 440.1R, which does not include provisions for anchorage to concrete. This research was conducted to begin filling that knowledge gap and determine if the equations for anchorage to concrete with steel reinforcing bars given in ACI 318 are appropriate for use with GFRP reinforcing bars. A series of tests were conducted with tensile and shear loading to characterize behavior of post-installed GFRP reinforcing bars and allow for comparison of their behavior to post-installed steel reinforcing bars. Specifically, two sizes of both steel and GFRP reinforcing bars (No. 5 and 8) were post-installed in concrete slabs using the same chemical adhesive. The confined and unconfined tensile strength of the bars away from concrete edges and in proximity to concrete edges was established. Additionally, shear tests on No. 5 bars were performed. Using the information gathered from these tests, the applicability of ACI 318 design guidelines for post-installed GFRP reinforcing bars is presented.

Keywords

Description

University of Minnesota M.S. thesis. December 2021. Major: Civil Engineering. Advisor: Benjamin Dymond. 1 computer file (PDF); xii, 199 pages.

Related to

Replaces

License

Series/Report Number

Funding information

Isbn identifier

Doi identifier

Previously Published Citation

Other identifiers

Suggested citation

DeMars, Thomas. (2021). Tensile and Shear Capacity of Post-Installed GFRP Bars in Concrete. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/226347.

Content distributed via the University Digital Conservancy may be subject to additional license and use restrictions applied by the depositor. By using these files, users agree to the Terms of Use. Materials in the UDC may contain content that is disturbing and/or harmful. For more information, please see our statement on harmful content in digital repositories.