Magnetic susceptibility is the degree of magnetization in response to an applied
magnetic field. While the expected magnetic susceptibility of subcellular components is
on the order of 9.05x10-6, variations in subcellular magnetic susceptibility as low as 10%
can create forces in the pN range within a cell when high intensity magnetic fields are
imposed. The objective of this study is to investigate the feasibility of two techniques to
measure the magnetic susceptibility of subcellular organelles. The sensitivity and
accuracy of resonance frequency shifts of microcantilever beams and magnetophoresis
are evaluated to ensure magnetic susceptibility measurements can be obtained within the
expected range for subcellular organelles.
The resonance frequency detection method was tested using a bismuth particle
and permanent magnets (B*dB/dz = 0.54 T2/m) to determine an uncertainty of 0.013 Hz.
To determine the technique feasibility for application to subcellular organelles, a
theoretical examination of resonance frequency shifts due to the application of magnetic
field and gradient products varying from 0.54 T2/m (permanent magnets) to 1300 T2/m
(superconducting magnet) was conducted for silicon, silicon nitride and polymer beams
of varying dimensions. Results indicate that only a polymer beam can produce a
detectable resonance frequency shift that is greater than the experimentally determined
uncertainty. However, an uncertainty smaller than 0.009 Hz is required to sense the
differences in resonance frequency shifts due to a 10% variance in magnetic
susceptibility. In summary, the microcantilever beam approach cannot achieve sufficient
sensitivity to detect the predicted differences among different subcellular organelle types.
ii
Tests implementing magnetophoresis for polystyrene test particles with a 100 μm
diameter explored the sensitivity and accuracy effects of varying fluid flow speeds of
0.63, 1.09, and 1.44 mm/sec, different particle radius to channel depth ratios (r/a) of
0.043 and 0.199, and a magnetic field and gradient product (B*dB/dz) of 38.91 T2/m.
Particle speed due to the magnetic field was recorded by a CCD camera with 32.68
pixels/mm resolution. The percent uncertainties of the experimental magnetic
susceptibilities are 12.3, 18.3 and 22.4% (in order of flow speed). The trial runs were
also used to determine that the smallest detectable magnetic velocity for the detection
method is 3.16 ± 15 μm /sec and the smallest detectable particle diameter is 31 μm. The
trial runs indicate that a balance of a larger r/a ratio and a slower flow speed is ideal to
optimize consistency in flow velocities and calculated magnetic susceptibilities while
minimizing uncertainty. A theoretical examination of organelle magnetic velocities due
to the application of magnetic field and gradient products of -38.91 T2/m and -1300 T2/m
indicates that the nuclei and large mitochondria are detectable in either magnetic field
while the small mitochondria is detectable only in the larger magnetic field. In addition,
all organelles have diameters smaller than 31 μm rendering them undetectable by the
current visualization method. The following recommendations are necessary to detect the
magnetic susceptibilities of subcellular organelles through magnetophoresis with
sufficient accuracy: use the larger B*dB/dz (-1300 T2/m), reorient the channel or
incorporate a level so that gravity is not a factor, and use a higher quality velocity
detection method.
Description
University of Minnesota M.S. thesis. November 2010. Major: Mechanical Engineering. Advisor: Susan C. Mantell. 1 computer file (PDF); xi, 86 pages, appendices A-C. Ill. (some col.)
Related to
Replaces
License
Series/Report Number
Funding information
Isbn identifier
Doi identifier
Previously Published Citation
Other identifiers
Suggested citation
Paukert, Emily Stewart. (2010). Techniques to identify the magnetic susceptibilty of subcellular organelles: a feasibility analysis.. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/103042.
Content distributed via the University Digital Conservancy may be subject to additional license and use restrictions applied by the depositor. By using these files, users agree to the Terms of Use. Materials in the UDC may contain content that is disturbing and/or harmful. For more information, please see our statement on harmful content in digital repositories.