A low power biosensor for medical applications
2014-08
Loading...
View/Download File
Persistent link to this item
Statistics
View StatisticsJournal Title
Journal ISSN
Volume Title
Title
A low power biosensor for medical applications
Authors
Published Date
2014-08
Publisher
Type
Thesis or Dissertation
Abstract
This research presents on a CMOS sensor, which includes a chopper stabilized front-end amplifier with DC suppressed feedback and a 12-bit successive approximation register (SAR) analog-to-digital converter (ADC) with background calibration. It could reduce the flicker noise interference in the low frequency and suppressed the DC offset voltage between the two input signals. Therefore, this structure is suitable for bio-medical applications. The bio-medical signals are smaller than 5 mV in the low frequency between 0.01 Hz and 1 kHz. After amplifying, the signals will be digitized by a 12-bit SAR ADC.The chopper stabilized amplifier has a clock rate, 16 kHz, controlling the chopper switches and shifting the original signals to 16 kHz in order to reducing the flicker noise. In our case, the flicker noise could lower at least 80 times at this clock rate. The two-Thomas Biquad low-pass filter, as the anti-aliasing filter, could suppress the harmonic signals at least 40dB before digitalized by ADC. For the 12-bit SAR ADC, the differential nonlinearity (DNL) is +0.576/-0.96 least significant bit (LSB), and the integral nonlinearity (INL) is +0.534/-0.655 LSB. The signal-to-noise and distortion ratio (SNDR) can be estimated 69dB. The effective number of bits (ENOB) is 11.17. The total power dissipation of the ADC is 60-µW at 500-KS/s sampling rate and the supply voltages are ±0.5V. The figure of merit (FOM) is 52.08-fJ/conversion step.
Description
University of Minnesota Ph.D. dissertation. August 2014. Major: Electrical Engineering. Advisor: Ted K. Higman. 1 computer file (PDF); vi, 68 pages.
Related to
Replaces
License
Collections
Series/Report Number
Funding information
Isbn identifier
Doi identifier
Previously Published Citation
Other identifiers
Suggested citation
Hu, Chia-Lin. (2014). A low power biosensor for medical applications. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/171174.
Content distributed via the University Digital Conservancy may be subject to additional license and use restrictions applied by the depositor. By using these files, users agree to the Terms of Use. Materials in the UDC may contain content that is disturbing and/or harmful. For more information, please see our statement on harmful content in digital repositories.