Hydraulic Model Study of the Market Avenue Retention Basin (MARB)

Loading...
Thumbnail Image

View/Download File

Persistent link to this item

Statistics
View Statistics

Journal Title

Journal ISSN

Volume Title

Title

Hydraulic Model Study of the Market Avenue Retention Basin (MARB)

Published Date

1998-12

Publisher

St. Anthony Falls Laboratory

Type

Report

Abstract

This report presents the results of a physical model study of the Market Avenue Retention Basin (MARB) located in Orand Rapids, Michigan. The model study was conducted for Dell Engineering, Inc. and the City of Orand Rapids, MI. The MARB described herein is a combined sewer overflow retention basin located in Orand Rapids, MI. The facility consists of a pumping station with ten pumps and three retention basins. The sump is designed to function through a ten foot operating range, with an additional pump coming on-line with each one foot rise in the sump level. The water enters the first basin through any of the ten pumps and discharges into Basin Two through an outfall channel when the elevation reaches 622 ft. Basin Two is a large triangular shaped area with eight elevated channels that water is allowed to overtop and enter Basin Three. Because this is a combined sewer plant the number of pumps in operation, and hence the pumping rate, varies with the magnitude of the storm event. Each 'PU1Tt1' is'rated at 105 million gallons per day (MOD), giving the maximum basin capacity of 1050 MOD when all ten pumps are in operation. The initial scope of this study focused on the hydraulic efficiency of Basin Two as a secondary sedimentation basin. The objective was to determine if short-circuiting occurred, and if so, to test various baffle arrangements to mitigate the short-circuiting. During the assessment process, it became clear that in addition to its capacity as a settling compartment, Basin Two was also being used as a disinfection chamber. With this in mind, and since it is impOliant for disinfection to occur properly, sufficient chlorine contact time with all effluent is necessary. Since the model study of the existing facility confirmed that the necessary contact time was not being achieved, alternative baffle designs were developed to increase the residence time to that needed for satisfactory disinfection. The results of this model study illustrate the efficiency of Basin Two as a sedimentation basin as well as a retention basin for chlorine disinfection. The information obtained from the experiments is given in the results section of the report and except where noted, all data has been scaled to existing facility values. A forty-minute video presentation supplements this report. The video shows the experimental runs for the three most favorable baffle designs at both 30% and 100% of the design flow.

Keywords

Description

Related to

Replaces

License

Collections

Series/Report Number

St. Anthony Falls Laboratory Project Reports
431

Funding information

Dell Engineering Inc.; City of Grand Rapids

Isbn identifier

Doi identifier

Previously Published Citation

Other identifiers

Suggested citation

Voigt, Richard L.; Tank, Julie A.. (1998). Hydraulic Model Study of the Market Avenue Retention Basin (MARB). Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/131898.

Content distributed via the University Digital Conservancy may be subject to additional license and use restrictions applied by the depositor. By using these files, users agree to the Terms of Use. Materials in the UDC may contain content that is disturbing and/or harmful. For more information, please see our statement on harmful content in digital repositories.