Retrospective Study on the Influence of Splinted Crowns of Multiple Adjacent Implants
2023-02
Loading...
View/Download File
Persistent link to this item
Statistics
View StatisticsJournal Title
Journal ISSN
Volume Title
Title
Retrospective Study on the Influence of Splinted Crowns of Multiple Adjacent Implants
Alternative title
Authors
Published Date
2023-02
Publisher
Type
Thesis or Dissertation
Abstract
Purpose: The purpose of this study was to retrospectively evaluate the effects of splinting implant crowns against nonsplinted crowns on the failures and complications of multiple adjacent implants.Material and Methods: A retrospective chart review was conducted of all registered implant patients treated at the University of Minnesota School of Dentistry in the span of 1988 to 2018. A total of 2738 implants of 1171 sections in 890 patients were examined retrospectively using an inclusion criteria of (1) at least two or more adjacent implants present and (2) implants were restored by Splinted crowns or Nonsplinted (individual) crowns.
Results: An average follow-up interval was significantly longer (p < 0.0001) for Splinted (median 5.52 [IQR 1.97, 9.67] years) compared to Nonsplinted (3.76 [1.49, 6.54] years). Splinted group’s Hazard ratio (HR) for implant failure was 0.67 (95% CI 0.35–1.31, p = 0.24) relative to Nonsplinted, and estimated 5-year and 10-year failures rates were 2.5 (1.3–3.7) vs. 3.0 (1.9–4.0)% and 8.7 (6.1–11.3) vs. 8.6 (5.7–11.3)%, respectively. Splinted group’s HR for total complication relative to Nonsplinted was 0.98 (95% CI 0.71–1.36, p = 0.92) and estimated 5-year and 10-year complication rates were 24.7 (21.7-27.5) vs. 23.7 (21.1-26.3)% and 38.1 (34.2-41.7) vs. 42.1 (37.2-46.6)%, respectively. Three most common complications (Splinted/Nonsplinted, 10-year estimates) were crown/cement debonding (20.8/13.0%), peri-implantitis (12.2/13.1%), and screw loosening (5.9/12.8%), while 3 failure causes (5-year estimates) were peri-implantits (1.8/1.3%), implant fracture/metal collar flowering (0.3/1.1%), and soft tissue encapsulation (0.1/0.2%). When 380 Lifecore implants were excluded, the implant failure HR became lower 0.46 (0.22–0.99, p = 0.05) indicating lower failure risk in Splinted compared to Nonsplinted, while the total complication HR did not change much 0.95 (0.64–1.40, p = 0.79). When compared per section, Splinted total complication HR went down to 0.75 (0.55–1.02, p = 0.07), indicating lower risk for complication in Splinted sections compared to Nonsplinted sections.
Conclusion: The trends of implant therapy of multiple adjacent implants have changed over the last three decades but the effects of splinting crowns of multiple adjacent implants were not significant in reducing implant failures or total complications.
Key words: multiple adjacent implants, splinted crowns, nonsplinted (individual) crowns, implant failures and complications
Keywords
Description
University of Minnesota M.S. thesis. February 2023. Major: Dentistry. Advisor: Wook-Jin Seong. 1 computer file (PDF); vi, 47 pages.
Related to
Replaces
License
Series/Report Number
Funding information
Isbn identifier
Doi identifier
Previously Published Citation
Other identifiers
Suggested citation
Chea, Yannie. (2023). Retrospective Study on the Influence of Splinted Crowns of Multiple Adjacent Implants. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/253713.
Content distributed via the University Digital Conservancy may be subject to additional license and use restrictions applied by the depositor. By using these files, users agree to the Terms of Use. Materials in the UDC may contain content that is disturbing and/or harmful. For more information, please see our statement on harmful content in digital repositories.