Abstract
Measurements of high concentration aerosols typically require some method to reduce the concentration of the aerosol to a measureable method. One common method is to use an aerosol diluter to reduce the aerosol concentration by a known value. Particle loss within the aerosol diluters can result in values of dilution that are particle size dependent and vary from the idealized volumetric dilution value.
Experiments were performed to measure the sub-100nm particle loss within aerosol diluters. The diluters tested include the TSI 3302, MSP 1100, a “leaky filter” laboratory diluters and a newly developed Orifice Diluter. Particle loss within aerosol diluters was found to be a significant effect, with up to 50% of the dilution being due to particle loss. Particle loss within the aerosol diluters was found to be primarily diffusion driven and loss within the diluters increased with decreasing particle diameter. A new terms was derived to describe particle loss within the aerosol diluters where diluter penetration describes the percentage of particle loss within an aerosol diluter.
Further investigation into particle charge found a significant reduction in particle penetration when the aerosol was singly charged. This can result as much as a 40% enhancement in particle loss.
Diluter penetration curves for the TSI 3302,MSP 1100, “leaky filter” and Orifice Diluters were then used to correct measurements of high concentration diesel aerosol. Correction methodology was found to be highly sensitive to the measured size distribution of the diesel aerosol. With accurate size distribution measurements the agreement between diluter and CPC combinations was corrected to less than 3% at a concentration of 1.57E5 cm-3 with a geometric mean diameter (GMD) of 50.0nm . As the GMD was reduced for the aerosol agreement among diluters was reduced, with a resulting agreement of ±4% at a GMD of 36.5 nm and ±25% at a GMD of 16.3nm. The decrease in agreement is due to the accuracy in the size distribution measurements.
Description
University of Minnesota M.S. thesis. December 2010. Major: Mechanical Engineering. Advisor: David B. Kittelson. 1 computer file (PDF); viii, 117 pages, appendices I-II. Ill. (some col.)
Related to
Replaces
License
Series/Report Number
Funding information
Isbn identifier
Doi identifier
Previously Published Citation
Other identifiers
Suggested citation
Collins, Aaron Michael. (2010). Ultrafine particle loss in aerosol diluters.. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/103245.
Content distributed via the University Digital Conservancy may be subject to additional license and use restrictions applied by the depositor. By using these files, users agree to the Terms of Use. Materials in the UDC may contain content that is disturbing and/or harmful. For more information, please see our statement on harmful content in digital repositories.