Repository logo
Log In

University Digital Conservancy

University Digital Conservancy

Communities & Collections
Browse
About
AboutHow to depositPolicies
Contact

Browse by Subject

  1. Home
  2. Browse by Subject

Browsing by Subject "Button heat pulse sensor"

Now showing 1 - 1 of 1
  • Results Per Page
  • Sort Options
  • Loading...
    Thumbnail Image
    Item
    Performance-Based Measurement of Optimum Moisture for Soil Compaction
    (Minnesota Department of Transportation, 2013-11) Hansen, Bradley J.; Nieber, John L.
    Part of the challenge achieving maximum field density in subgrade materials is transferring the optimal compaction and moisture content data from laboratory testing to the field. This research investigated the proficiency of four different instruments at accurately predicting moisture contents of three subgrade soils (loam, silt, silty/clay) commonly used in Minnesota roadway construction projects. The four instruments were; DOT600 (moisture content), WP4C dewpoint potentiometer (matric suction), the Button Heat Pulse Sensor (BHPS) (temperature rise vs. moisture content), and an exudation pressure test device. The DOT600 showed a strong correlation between the output period (measured in micro-seconds) and volumetric water content. The WP4C did not accurately measure matric suction for any of the loam, silt or silt/clay soils at suctions below 250 kPa. Published data shows that the matric suction of soils compacted at optimum moisture content is usually in the range of 200 – 300 kPa. The BHPS showed a strong correlation between measured temperature rise and water content but in its current configuration is not rigorous enough to withstand field conditions. The exudation pressure device was applied to soils compacted in a AASHTO T99 mold at various moisture contents. Water was exuded from the packed samples at pressures between 100 and 500 psi corresponding to AASHTO-T99 moisture contents of 10 to 25 %. Accurate moisture content readings from any of these instruments may not be as important as a more precise and simple calibration between the measurement units of the instrument and the optimum moisture content determined from the AASHTO T99 test.

UDC Services

  • About
  • How to Deposit
  • Policies
  • Contact

Related Services

  • University Archives
  • U of M Web Archive
  • UMedia Archive
  • Copyright Services
  • Digital Library Services

Libraries

  • Hours
  • News & Events
  • Staff Directory
  • Subject Librarians
  • Vision, Mission, & Goals
University Libraries

© 2025 Regents of the University of Minnesota. All rights reserved. The University of Minnesota is an equal opportunity educator and employer.
Policy statement | Acceptable Use of IT Resources | Report web accessibility issues