LOW VOLTAGE / LOW POWER RAIL-TO-RAIL CMOS OPERATIONAL AMPLIFIER FOR PORTABLE ECG A DISSERTATION SUBMITTED TO THE FACULTY OF THE GRADUATE SCHOOL OF THE UNIVERSITY OF MINNESOTA BY BORAM LEE IN PARTIAL FULFILLMENT OF THE REQUIREMENTS FOR THE DEGREE OF DOCTOR OF PHILOSOPHY Ted Higman August 2013 © Copyright by BORAM LEE 2013 i Acknowledgements First of all, I wish to thank God for his guidance and love for me throughout my life up to this moment and praise the Lord with all my heart. His amazing grace has always been with me and will guide me for the rest of my life. I would like to give my very special thanks to Professor Higman, my advisor. Without his help, I would never have been able to complete my degree successfully. His help gave me the very last chance and that chance changed my life. I am immensely blessed with many wonderful people. Most of all, I would like to show my sincere appreciation to my dear friends, ‘Siete Amigos’. And I also would like to thank Korean students of Electrical Engineering, especially Kyubaek, Sungmin, Hweerin, Jaehyup, Kicheol, and Youngil. The members of Korea University Alumni Association at Minnesota are also very helpful for me to encourage and refresh. Finally, I want to express my deepest appreciation and love to my family, beloved parents, my sister and brother-in-law Chip, adorable wife Sora and lovely son Luke, for their unlimited love and support. ii Abstract One of the most important building blocks in modern IC design is the operational amplifier. For the portable electrocardiogram (ECG), the operational amplifier is employed to sense and amplify the electrical signal of heartbeat of human body. For the battery powered portable ECG system, low supply voltage environments are required to reduce power consumption and the result is a reduced input common mode range (ICMR) of the op-amp. To overcome the reduced ICMR problem, complementary differential pairs operated in parallel are commonly used to achieve a rail-to-rail input common mode range. However, this complementary differential input pair structure can have a substantial transconductance (gm) variation problem and a dead zone problem in a low supply voltage environment and an extremely low supply voltage environment respectively. In the past years, a number of techniques have been proposed to overcome those problems for low- and extremely low-supply voltage environments. This dissertation is focused on an op-amp applicable to a portable ECG system and in total five novel rail-to-rail constant gm op-amps usful for circuits such as a portable ECG are proposed. Three of those op-amps work in the low supply voltage environment and two op-amps are proposed for the extremely low supply voltage environment. Cadence SPECTRE simulation and TSMC 0.25-µm CMOS technology are used to simulate and lay out these works. iii Table of Contents Acknowledgements ............................................................................................................ i Abstract .............................................................................................................................. ii Table of Contents ............................................................................................................. iii List of Tables ..................................................................................................................... v List of Figures ................................................................................................................... vi Chapter 1. Introduction ................................................................................................. 1 1.1 Background and Motivation ................................................................................. 1 1.2 Requirements of Portable ECG Amplifier ............................................................ 5 1.3 Organization of The Dissertation .......................................................................... 8 Chapter 2. Literature Review for Low Supply Voltage Op-Amp ........................... 10 2.1 Low Supply Voltage Environment ..................................................................... 10 2.2 Tail Current Control Technique .......................................................................... 11 2.3 Maximum/Minimum Current Selection Technique ............................................ 16 2.4 Level Shifting Technique .................................................................................... 19 Chapter 3. Novel Low Supply Voltage Rail-to-Rail Op-Amps ................................ 22 3.1 New Level Shifting Technique : The Simplest Technique ................................. 22 3.2 Saturation Point Control Technique .................................................................... 27 3.3 Modified New Level Shifting Technique : Hybrid of 3.1 and 3.2 ...................... 36 Chapter 4. Literature Review for Extremely Low Supply Voltage Op-Amp ......... 40 4.1 Extremely Low Supply Voltage Environment .................................................... 40 4.2 Dynamic Level Shifting Technique .................................................................... 41 4.3 Bulk Driven Input Stage Technique ................................................................... 45 iv 4.4 Depletion Mode Input Pair Technique ................................................................ 47 4.5 Input Signal Compression Technique ................................................................. 49 Chapter 5. Novel Extremely Low Supply Voltage Rail-to-Rail Op-Amps ............. 53 5.1 Common Mode Elimination Technique .............................................................. 53 5.2 New Input Signal Compression Technique ........................................................ 57 Chapter 6. Simulation Results and Comparison ....................................................... 64 6.1 Simulation Results of New Level Shifting Technique ....................................... 64 6.2 Simulation Results of Saturation Point Control Technique ................................ 72 6.3 Simulation Results of Modified New Level Shifting Technique ........................ 77 6.4 Simulation Results of Common Mode Elimination Technique .......................... 83 6.5 Simulation Results of New Input Signal Compression Technique ..................... 87 Chapter 7. Conclusion ................................................................................................. 99 Bibliography .................................................................................................................. 101 Appendix ........................................................................................................................ 107 v List of Tables Table 6.1 Simulation Results of Conventional and New Level Shifting Techniques .................... 67 Table 6.2 Simulation Results Comparison of Before and After Noise Reduction ......................... 70 Table 6.3 Comparison of Schematic and Post Layout Simulation Results .................................... 72 Table 6.4 Simulation Results Comparison of Before and After Noise Reduction ......................... 75 Table 6.5 Comparison of Schematic and Post Layout Simulation Results .................................... 77 Table 6.6 Schematic Simulation Results Comparison of Two Techniques ................................... 79 Table 6.7 Post Layout Simulation Results Comparison of Two Techniques ................................ 82 Table 6.8 Overall Simulation Results Comparison of Low Supply Voltage Techniques .............. 82 Table 6.9 Schematic Simulation Results Comparison of Two Techniques ................................... 86 Table 6.10 Schematic Simulation Results Comparison of Three Techniques ............................... 90 Table 6.11 Schematic Simulation Results Comparison of New input Signal Compression Technique ....................................................................................................................................... 92 Table 6.12 Comparison of Schematic and Post Layout Simulation Results ................................. 95 Table 6.13 Schematic Simulation Results Comparison of All Five Novel Techniques without Noise Reduction ............................................................................................................................. 96 Table 6.14 Post Layout Simulation Results Comparison of Four Novel Techniques .................... 96 Table A. 1 Simulation Results Comparisons of Strong and Weak Inversion Regions Operation 108 vi List of Figures Figure 1.1 Complementary Input Differential Pair Structure .......................................................... 2 Figure 1.2 Working Principle and Total Gm Variation of Low Supply voltage Environment ........ 3 Figure 1.3 Working Principle and Dead Zone of Extremely Low Supply voltage Environment .... 4 Figure 1.4 Structure of the Instrumentation Amplifier .................................................................... 6 Figure 2.1 Tail Current Control using Square Root Current Circuit .............................................. 12 Figure 2.2 Tail Current Control using Current Switch .................................................................. 14 Figure 2.3 Tail Current Control using Hex-Pair Structure ............................................................. 15 Figure 2.4 Maximum Current Selection Technique ....................................................................... 16 Figure 2.5 Total Transconductance of Maximum Current Selection Technique ........................... 17 Figure 2.6 Minimum Current Selection Block ............................................................................... 18 Figure 2.7 Minimum Current Selection Technique ....................................................................... 18 Figure 2.8 Input Stage of Level Shifting Technique ...................................................................... 20 Figure 2.9 Total Transconductance of Level Shifting Technique .................................................. 20 Figure 3.1 Structure Comparison of Conventional and New Level Shifting Technique ............... 23 Figure 3.2 Comparison of Total Transconductance Variation ....................................................... 25 Figure 3.3 Simulation Results of Total Transconductance Variation ............................................ 26 Figure 3.4 Total Transconductance Variations with 1.6V, 1.4V, and 1.2V ................................... 28 Figure 3.5 Structure and Working Principle of Saturation Point Control Technique .................... 31 Figure 3.6 Modified Saturation Point Control Technique ............................................................. 33 Figure 3.7 Total Transconductance Variations with Supply Voltage of 1.6V, 1.4V, and 1.2V .... 35 Figure 3.8 Structure and Working Principle of Modified New Level Shifting Technique ............ 37 Figure 3.9 Comparison of Total Transconductance Variations ..................................................... 39 Figure 4.1 Basic Concept of Dynamic Level Shifting Technique ................................................. 42 vii Figure 4.2 Current Generator Block & Shifted Common Mode Voltages .................................... 44 Figure 4.3 Comparison of Gate Driven and Bulk Driven [19] ...................................................... 46 Figure 4.4 Concept of Bulk Driven Input Technique .................................................................... 46 Figure 4.5 Current Characteristic Comparison .............................................................................. 48 Figure 4.6 Concept of Depletion Mode Input Pair Technique ....................................................... 48 Figure 4.7 Hybrid Type of Depletion Mode Input and Bulk Driven Input Techniques ................ 49 Figure 4.8 Basic Concept of Input Signal Compression Technique .............................................. 50 Figure 4.9 Basic Concept of Input Signal Compression Technique .............................................. 51 Figure 5.1 Structure of Common Mode Elimination Technique ................................................... 54 Figure 5.2 Basic Concept of Common Mode Elimination ............................................................. 54 Figure 5.3 Differential Input Signal Extraction ............................................................................. 55 Figure 5.4 Comparison of Minimum CMRR ................................................................................. 56 Figure 5.5 Structure of New Input Signal Compression Technique .............................................. 58 Figure 5.6 Structure and Working Principle of Block ‘1’ .............................................................. 59 Figure 5.7 Structure and Working Principle of Block ‘2’ .............................................................. 60 Figure 5.8 Concept of differential Signal Extraction and Compensation ...................................... 61 Figure 5.9 Comparisons of Gain and Unity Gain Frequency......................................................... 61 Figure 5.10 Comparison of Transferred Differential Input Signal ................................................ 62 Figure 6.1 Overall Structure Comparison ...................................................................................... 65 Figure 6.2 Comparison of Conventional and New Level Shifting Technique ............................... 66 Figure 6.3 Input Referred Noise of New Level Shifting Technique .............................................. 68 Figure 6.4 Simulation Results Comparisons of Before and After Noise Reduction ...................... 69 Figure 6.5 Layout Picture of New Level Shifting Technique (125.82µm×93.18µm) ................... 70 Figure 6.6 Comparisons of Schematic and Post Layout Simulations ............................................ 71 Figure 6.7 Overall Structure of Saturation Point Control Technique ............................................ 73 viii Figure 6.8 Simulation Results Comparisons of Before and After Noise Reduction ...................... 74 Figure 6.9 Layout of Saturation Point Control Technique (118.38µm×83.1µm) .......................... 75 Figure 6.10 Comparisons of Schematic and Post Layout Simulations .......................................... 76 Figure 6.11 Overall Structure Comparison of New and Modified New Level Shifting Technique ....................................................................................................................................................... 78 Figure 6.12 Schematic Simulation Results Comparison of Two Techniques ................................ 79 Figure 6.13 Input Referred Noise Comparison of Two Techniques .............................................. 80 Figure 6.14 Layout Picture of Modified New Level Shifting Technique (128.7µm×93.18µm) ... 80 Figure 6.15 Post Layout Simulation Results Comparison of Two Techniques ............................. 81 Figure 6.16 Overall Structure Comparison of Input signal Compression Technique and Common Mode Elimination Technique ........................................................................................................ 84 Figure 6.17 Schematic Simulation Results Comparison of Two Techniques ................................ 85 Figure 6.18 Overall Structure of New Input Signal Compression Technique ............................... 88 Figure 6.19 Schematic Simulation Results Comparison of Three Techniques .............................. 89 Figure 6.20 Schematic Simulation Results Comparison of Before and After Noise Reduction .... 91 Figure 6.21 Layout Picture of New Input Signal Compression Technique (207.78µm×119.46µm) ....................................................................................................................................................... 93 Figure 6.22 Comparison of Schematic and Post Layout Simulation Results................................. 94 1 Chapter 1. Introduction 1.1 Background and Motivation One of the main trends of electronic biomedical devices is portability and wireless operation. Because, for the future healthcare services, portable electronic health monitoring devices will enable 24 hour health monitoring, home healthcare systems, early detection of diseases and so on. Electrocardiogram (ECG) is one of the electronic biomedical systems which senses the electrical signal of the heartbeat to detect abnormal rhythms of the heart. A conventional ECG system, however, is very bulky and not convenient for 24 hour monitoring due to wired connections. Portable ECG facilitates 24 hour monitoring for patients who have heart diseases and need cardiac monitoring in their everyday life. With this trend of battery powered health monitoring systems, portable biomedical devices demand circuits operating in low supply voltage. In the ECG system, an op-amp often senses and amplifies the electrical signal of the heart. The op-amp of the portable ECG may have to be operated in low supply voltage environments for lower power consumption and the result of lowered supply voltage is a reduced input common mode range (ICMR) of the op-amp. A commonly used way to overcome reduced ICMR problem and ensure rail-to-rail input common mode signal is complementary differential pairs operated in parallel (Figure 1.1). Because both N-type and P-type differential pairs are employed in the input stage, the entire range 2 of supply voltage, rail-to-rail, can be an input common mode range. One problem with the complementary differential pair structure, however, is overall transconductance (gm) variation in the middle range of the common mode input signal. There are two possible situations according to the environment of supply voltage. The first situation is about two times the transconductance variation problem with low supply voltage environment and the second is dead zone problem with extremely low supply voltage environment. Figure 1.2 shows that the working principle of complementary input differential pair structure and the transconductance variation problem with a low supply voltage environment. In Figure 1.2 (a), if a single input differential pair, either N-type or P-type, is used, the turn off region of the input common mode voltage of N-type or P-type input will limit a portion of the ICMR. The complementary input differential pair structure employs both of N-type and P-type input differential pairs and ensures rail-to-rail input common mode voltage range. The problem of this structure, however, with low supply Figure 1.1 Complementary Input Differential Pair Structure 3 voltage is that there is an approximately two-fold transconductance variation throughout the common mode input range which results in a variable unity gain frequency and a stability problem. Figure 1.2 (b) shows the total transconductance variation problem with low supply voltage. Both N-type and P-type input differential pairs are turned on at the same time in the middle range of common mode input signal and that causes about two times the transconductance variation. In the past years, a number of constant gm (a) Currents of Complementary Input Differential Pair Structure (b) Total Transconductance Variation with Low Supply Voltage Figure 1.2 Working Principle and Total Gm Variation of Low Supply voltage Environment 4 techniques are proposed to overcome the transconductance variation problem of a low supply voltage environment and three typical techniques are briefly explained in chapter 2. The situation of an extremely low supply voltage environment is totally different from the case of low supply voltage environment. With extremely low supply voltage, both of N-type and P-type differential input pairs of complementary input differential pair (a) Currents of Complementary Input Differential Pair Structure (b) Total Transconductance Variation with Extremely Low Supply Voltage Figure 1.3 Working Principle and Dead Zone of Extremely Low Supply voltage Environment 5 structure are turned off or triode region in the middle range of common mode input signal. Figure 1.3 shows currents of input pairs and total transconductance variation of the extremely low supply voltage environment. Because the both input pairs are turned off or in the triode region, the total transconductance is very small or almost zero in the middle range of common mode input signal. Thus, this region is called the ‘dead zone’. A few techniques are previously introduced to avoid the dead zone problem and some typical techniques are explained in chapter 4. In this dissertation, five novel techniques are proposed. The first three are new level shifting technique, saturation point control technique, and modified new level shifting technique and these three techniques are working in low supply voltage environment. The other techniques are common mode elimination technique and new input signal compression technique. Those techniques can be made to work in the extremely low supply voltage environment. 1.2 Requirements of Portable ECG Amplifier A conventional ECG system usually employs an instrumentation amplifier which is also employed by other biomedical instruments such as EEG, EMG, and so on. Figure 1.4 shows the structure of the instrumentation amplifier and this structure has some intrinsic characteristics which are suitable for ECG system. First, the instrumentation amplifier has very high input impedance. For ECG systems, electrodes are usually used to sense the electrical signal of heartbeat and a high input impedance is required for the 6 ECG amplifier because of high impedance of electrode. The minimum allowable input impedance of the ECG amplifier is typically 10 MΩ ([3]) which is easily achieved in a MOSFET amplifier since the input of the instrumentation amplifier is directly connected to the gate of MOSFET and its input impedance is very high. The second requirement of ECG amplifier is high common mode rejection ratio (CMRR). The ECG system is required to sense only the cardiac signal and reject all other electrical common mode signals typically from larger muscles in the body. In Figure 1.4, if and which are two inputs of the instrumentation amplifier have same voltage, the current which flow through resistor is ideally zero and the voltage of and are the same. Thus, there is no amplification of common mode voltage and the instrumentation amplifier has very high CMRR. The third is a gain that can be changed by adjusting . The gain of the instrumentation amplifier is expressed as below. Figure 1.4 Structure of the Instrumentation Amplifier 7 There are two registers for , , and , while only one register is required for (Figure 1.4). Hence, the gain of the instrumentation amplifier is easily controlled by adjusting . For the amplifier of the portable ECG system, low power consumption is required as well as all other requirements for the conventional ECG system mentioned before. Basically, the portable ECG system is battery powered and for more battery life, low power consumption and low supply voltage for an amplifier is essential. This dissertation is focused on an operational amplifier for the portable ECG with low supply voltage and extremely low supply voltage environment. Listed below are some target specifications for the novel low supply voltage rail- to-rail op-amps proposed in this dissertation. Gains of all amplifiers are larger than 40dB and 3dB frequencies are around 150Hz. Phase margins are larger than 55º. In [4], acceptable input referred noise of ECG amplifier is 30µVp-p and 5µV/√ at 1Hz of input referred noise is good enough for ECG signal acquisition [3]. Large transistor sizes are used to reduce flicker noise at low frequencies and input referred noise is about 5µV/√ at 1Hz. CMRR, unity gain frequency, average power consumption, supply voltage, and gain variation of all proposed op-amps are compared with each other using post layout simulation results in Chapter 6. 8 1.3 Organization of The Dissertation This dissertation is divided into seven chapters. Following this introduction, previously introduced rail-to-rail amplifiers for low supply voltage environment are described in Chapter 2. The low supply voltage environment is explained first and three typical rail-to-rail techniques are described. Three typical rail-to-rail techniques for the low supply voltage environment are tail current control technique, maximum/minimum current selection technique and level shifting technique. Not all rail-to-rail constant-gm techniques for low supply voltage amplifier can be categorized in these three techniques, but these techniques are typical method for constant-gm of rail-to-rail operational amplifier with low supply voltage. In Chapter 3, three novel rail-to-rail constant-gm techniques for the low supply voltage environment are proposed. The first technique is new level shifting technique. This technique has similar concept with the conventional level shifting technique. For this novel technique, however, only one diode connected NMOS is required and that is the simplest method for rail-to-rail constant-gm op-amp. The second one is saturation point control technique. This is novel transition regions technique and proposed to overcome drawback of conventional and new level shifting technique. The last technique is the modified new level shifting technique which is hybrid of new level shifting technique and saturation point control technique. The transconductance variation of the new level shifting technique can be reduced considerably using this technique. 9 Literature review for previous technique of extremely low supply voltage rail-to- rail op-amp is given in Chapter 4. Previously introduced techniques are dynamic level shifting technique, depletion mode input pair technique, bulk driven input stage technique and input signal compression technique. Two novel techniques for extremely low supply voltage rail-to-rail constant-gm op-amps are proposed in Chapter 5. The common mode elimination technique is the first technique. This technique employs conventional input signal compression technique and signal inverting blocks are introduced with resistors to eliminate the common mode input signal. Because the common mode input signal is eliminated, very high CMRR is achieved. The new input signal compression technique, is the second technique for the extremely low supply voltage environment, and has the same basic concept as the common mode elimination technique, but conventional input signal compression blocks are replaced by a new input signal compression block to improve bandwidth and noise performance, and reduce complexity. In Chapter 6, all the post layout simulation results are shown and all proposed techniques are compared. The conclusion is given in Chapter 7. 10 Chapter 2. Literature Review for Low Supply Voltage Op-Amp 2.1 Low Supply Voltage Environment As mentioned in Chapter 1, a low supply voltage often results in a reduced input common mode range problem. The conventional complementary differential input pair structure which overcomes reduced ICMR problem and ensures rail-to-rail input common mode range has double the transconductance in the middle range of the input common mode signal when compared to the higher and lower voltage regions of the common mode signal. This doubled transconductance variation implies a two-fold variation of gain and two-fold variation in unity gain frequency. The unity gain frequency variation can cause serious stability problems. When the compensation capacitor is optimized for sufficient phase margin for stable operation, the unity gain frequency varies by a factor of two depending on the value of input common mode voltage, and consequently the phase margin may not be enough and the whole system may be unstable for certain values of common mode input (usually midway between the power supplies). Therefore, constant transconductance as a function of common mode input is desirable for a low supply voltage rail-to-rail op-amp. For this reason, several constant transconductance techniques for low supply voltage rail-to-rail op-amp are proposed in the past. Three typical 11 techniques from among those techniques are briefly explained in the following sections of this chapter. 2.2 Tail Current Control Technique The first typical technique for low supply voltage rail-to-rail op-amp is the tail current control technique. In the low supply voltage environment, both N-type and P-type input differential pairs of the complementary input pairs structure are turned on at the same time in the middle range of the common mode input signal and the currents of the middle range of both input pairs cause two times the transconductance variation (Figure 1.2). Thus, if the currents of both input pairs are controlled in the middle range of the common mode input signal, the total transconductance can be kept constant. The currents and transconductance of input pairs, and the total transconductance are expressed as below. ( ) ( ) √ ( ) √ √ (√ √ ) (if ) From the above equations, for the constant total transconductance, (√ √ ) must be kept constant in the whole range of input common mode signal, because is constant. Therefore, in the middle range of input common mode signal, and should be one quarter of of high input common mode voltage and of low common mode voltage. 12 A number of techniques employ this tail current control technique and Figure 2.1 shows the concept of this technique and total transconductance variation ([5]~[7]). Some equations for explanation of this circuit are given below. (a) Concept of Constant Square Root Current Circuit (b) Total Transconductance Variation with Square Root Current Circuit Figure 2.1 Tail Current Control using Square Root Current Circuit 13 √ ⁄ | | √ ⁄ | | √ √ √ √ √ √ The sum of source gate voltage difference, , of M1 and M2 is same as the sum of of M4 and M5. From the above equation, the sum of the square roots of and is constant. And the currents of M4 and M5 are same with and . and are currents of NMOS and PMOS input pairs, respectively. Therefore, (√ √ ) can be kept constant and as a result, the total transconductance is constant in the whole range of input common mode signal (Figure 2.1 (b)). Another method to control tail current is introduced in [8]~[10]. This technique employs current switch to control tail current and conceptual circuit of this technique is shown in Figure 2.2. When NMOS or PMOS input pair is turned off, the switch 2 (SW2) or the switch 1 (SW1) diverts tail current , respectively. Using 1:3 current mirror, 3 is added to tail current of PMOS or NMOS input pair. As a result, the total current of NMOS or PMOS input pair when the common mode input signal is close to Vdd or Vss is 4 . Thus, (√ √ ) and the total transconductance can be kept 14 constant in the whole range of input common mode signal. The above square root circuit and 1:3 current mirror circuit, however, have two limitations. The first limitation is that both techniques are based on drain current quadratic characteristic. Those techniques cannot apply to deep sub-micrometer CMOS devices because deep sub-micrometer CMOS devices do not follow quadratic characteristic accurately. The second is two times variation of slew rate. The above two techniques has two times the total current of input stage variation and that causes slew rate variation. In [11], hex-pair structure is proposed to overcome these limitations. The circuit of input stage of this technique is shown in Figure 2.3. There are three PMOS input pairs and three NMOS input pairs. When the common mode input signal is close to Vss, only PMOS input pairs, block P1 and block P2, are turned on. The total current of Figure 2.2 Tail Current Control using Current Switch 15 block P1 is 2 and one of this total current is diverted to block N2. Thus, 2 , one from block P1 and another from block P2, are transferred to the folded cascode current summing stage. When the common mode input signal is close to Vdd, only the input pairs of block N1 and N2 are turned on and, with the same working principle of PMOS input pairs’ case, 2 are transferred to the next stage. In the middle range of input common mode signal, only the input pairs of block P1 and block N1 are turned on. One from block P1 is diverted to block N2 and NMOS input pair of block N2 is turned off. And one from block N1 is diverted to block P2 and PMOS input pair of block P2 is turned off. Hence, 2 , one from block P1 and another from block N1, are transferred to the next stage. Because the total currents of input pairs are always 2 in the whole range of input common mode signal, there are no significant variations of total transconductance and slew rate. Figure 2.3 Tail Current Control using Hex-Pair Structure 16 2.3 Maximum/Minimum Current Selection Technique The maximum/minimum current selection technique is the second typical technique for low supply voltage rail-to-rail op-amp. The basic concept of this technique is only the current of one pair, larger or smaller current, is transferred to the next stage. Therefore, the only one input pair’s transconductance can affect the total gain. Maximum current selection technique is introduced in [13] and Figure 2.4 shows the circuit of the input stage of maximum current selection technique. When the current of PMOS input, (a) Circuit of Maximum Current Selection Technique (b) Maximum Current Selection Block Figure 2.4 Maximum Current Selection Technique 17 , is larger than the current of NMOS input, , the currents of M1 and M2, and , equal (Figure 2.4 (b)). Because is smaller than , the current of M3, , equals . In this situation, M4 is turned off and the currents of M4 and M5, and , are zero. Thus, equals , because equals sum of and . On the contrary, if is larger than , the currents of M1, M2, and M3 equal . Then, the currents of M4 and M5 are . Therefore, equals , because equals sum of and , . As a result, only the larger current and the larger transconductance can be transferred to the folded cascode current summing stage. Figure 2.5 shows the total transconductance variation of maximum current selection technique. In [12], the minimum current selection technique (which has a similar concept to the maximum current selection technique) is proposed. The circuit of the minimum current selection block is illustrated in Figure 2.6. If is larger than , and . is , because is sum of and . equals and is sum of and . So, equals , because . Figure 2.5 Total Transconductance of Maximum Current Selection Technique 18 On the other hand, when is smaller than , . In this situation, M2 works in triode region and M3 and M4 are turned off. Thus . As a result, the smaller current is selected as for all cases. Figure 2.7 shows the input stage circuit of minimum current selection technique. Two input currents of the minimum current selection block are and . When the current of NMOS input pair, , is larger than the current of PMOS pair, , Figure 2.6 Minimum Current Selection Block Figure 2.7 Minimum Current Selection Technique 19 is smaller than , and will be the output current of the minimum current selection block. Thus, the transconductance of NMOS input pair is transferred to the folded cascode current summing stage. If is larger than , will be the output current of the minimum current selection block, and the transconductance of PMOS input pair is transferred to the next stage. As a result, total transconductance variation is same with the maximum current selection technique (Figure 2.5). 2.4 Level Shifting Technique The previously explained techniques, in Chapter 2.3 and 2.4, require additional complex circuitry and often have degraded CMRR. To overcome these drawbacks, a simple constant transconductance rail-to-rail technique is proposed in [1]. This technique is level shifting technique and the input stage of this technique is illustrated in Figure 2.8. In this technique, two PMOS source followers are used for common mode input level shifting. The input signal of the amplifier is directly connected to the input of a PMOS source follower and N-channel input differential pair, and the output of the PMOS source follower is connected to the input of the P-channel differential pair. Thus, the shifted input signal is fed to the input of the P-channel differential pair. | | | | | | 20 Where is the shifted input signal (by the PMOS source follower) and is the PMOS transistor gate-source voltage, and and are the overdrive voltage and threshold voltage of the PMOS transistor, respectively. The current and transconductance of P-channel input differential pair are shifted towards the negative as much as | |. As Figure 2.8 Input Stage of Level Shifting Technique Figure 2.9 Total Transconductance of Level Shifting Technique 21 a result, the transition regions of the N-channel and P-channel input differential pairs are overlapped. The overall transconductance variation is shown in Figure 2.9. If PMOS source followers are not used to shift input common mode signal, the overall transconductance has doubles in the middle range of input common mode signal (Figure 1.2 (b)). But the transconductance of the PMOS input pair is shifted by the PMOS source follower and transition regions of NMOS and PMOS are overlapped (Figure 2.9). Therefore, total transconductance can be kept constant in the whole range of input common mode signal. 22 Chapter 3. Novel Low Supply Voltage Rail-to-Rail Op-Amps In Chapter 2, some typical techniques which are previously proposed in the past years are briefly explained. In this chapter, three novel techniques for a constant transconductance rail-to-rail op-amp of low supply voltage environment are introduced. The first technique is new level shifting technique and the second one is saturation point control technique. The last technique is modified new level shifting technique which is hybrid of the first and the second technique. 3.1 New Level Shifting Technique : The Simplest Technique The conventional level shifting technique is proposed in [1] and briefly explained in Chapter 2. In [1], 1.2µm CMOS technology is used and the supply voltage is ±1.5V. New level shifting technique is designed with TSMC 0.25µm CMOS technology and 1.6V single supply voltage. For direct comparison, the conventional level shifting technique is re-designed and simulated with TSMC 0.25µm CMOS technology and 1.6V single supply voltage. As explained in Chapter 2.4, the conventional level shifting technique is very simple and has no serious degradation of CMRR. New level shifting technique, however, 23 has same concept and more simple structure. The conventional level shifting technique requires two PMOS source followers, totally four MOSFETs, but only one diode connected NMOS is employed for new level shifting technique. Figure 3.1 shows structure comparison of these two techniques. Figure 3.1 (a) is the input stage structure of (a) Input Structure of Conventional Level Shifting Technique (b) Input Structure of New Level Shifting Technique Figure 3.1 Structure Comparison of Conventional and New Level Shifting Technique 24 the conventional level shifting technique. Because of two PMOS source followers, the common mode input signal of PMOS differential input pair is shifted as much as | | | | and the current and transconductance of PMOS input pair are shifted towards the negative as much as | | of PMOS source follower. Figure 3.1 (b) shows the structure of new level shifting technique. There are complementary differential input pair operated in parallel and only one diode connected NMOS is added above the tail current source of the N-channel differential input pair. If a diode connected NMOS is not added, the structure is simply a conventional complementary differential input pair operated in parallel and the transconductance of the amplifier varies from gm to about 2gm in the middle range of the common mode input. For this conventional complementary differential input pair, the minimum input voltage of the N-channel input differential pair is given below. In the above equation, is the overdrive voltage of NMOS tail current source and is the gate-source voltage difference of the N-channel input differential pair. For the case of the proposed novel structure, the minimum input voltage of N-channel input differential pair is given below. As shown in the above equation, another is required because of diode connected NMOS above the NMOS tail current source. Thus, the current and transconductance of N-channel input differential pair are shifted as much as . If | | of PMOS source 25 follower of the conventional level shifting technique is same with of diode connected NMOS of new level shifting technique, the shifting amount of two techniques is exactly same and the total transconductance variations have same result. Figure 3.2 shows the comparison of total transconductance variation concepts of two techniques. (a) Total Transconductance Variation of Conventional Level Shifting Technique (b) Total Transconductance Variation of New Level Shifting Technique Figure 3.2 Comparison of Total Transconductance Variation 26 Figure 3.3 shows the simulation results of the total transconductance variations. Figure 3.3 (a) is the case of the conventional level shifting technique with 1.6V single supply voltage and TSMC 0.25µm technology. The result shows ±4.97% of total transconductance variation. The simulation result of new level shifting technique is shown in Figure 3.3 (b). Because of addition of diode connected NMOS, the slope of (a) Simulation Result of Conventional Level Shifting Technique (b) Simulation Result of New Level Shifting Technique Figure 3.3 Simulation Results of Total Transconductance Variation 27 transition region of NMOS is gentler than that of PMOS. This mismatch cause larger total transconductance variation and the result shows ±8.66% of total variation. To reduce this larger total transconductance variation, modified new level shifting technique is proposed in Chapter 3.3. New level shifting technique proposed in this chapter requires only one MOSFET for a constant transconductance and that is the simplest technique for a rail-to-rail op-amp with low supply voltage environment. One drawback of this technique is relatively large total transconductance variation. 3.2 Saturation Point Control Technique As mentioned before, the advantages of conventional and modified overlapped transition regions techniques using voltage level shifting are simplicity and high CMRR. One of the main drawbacks of those techniques, however, is a limited amount of voltage shifting. The comparison of two techniques, the conventional and new level shifting technique, is given in Chapter 3.1 with 1.6V single supply voltage. However, if supply voltage is lower than 1.6V, required amount of voltage shifting for a constant transconductance is smaller than what is required for a 1.6V supply voltage. Because of the minimum required for active mode operation of transistors, the voltage shifting amount of input common mode signal cannot be lower than the power supply limited amount of voltage shifting. Even if the shifted amount of input common mode signal is lower than the limited amount using sub-threshold current, the aspect ratio of transistors 28 which are used to shift common mode input signal should be extremely large and those transistors cannot be used practically. (a) 1.6V Single Supply Voltage (b) 1.4V Single Supply Voltage (c) 1.2V Single Supply Voltage Figure 3.4 Total Transconductance Variations with 1.6V, 1.4V, and 1.2V 29 Figure 3.4 shows the simulation results of total transconductance variation for the conventional and new level shifting technique with the supply voltage of 1.6V, 1.4V, and 1.2V. TSMC 0.25-µm technology is used to simulate this work and the minimum threshold voltages of PMOS and NMOS are about -500mV and 450mV which are the minimum required for active mode operation of PMOS source follower and diode connected NMOS, respectively. The required voltage shifting amount for a constant transconductance is 550mV, 330mV, and 110mV with 1.6V, 1.4V, and 1.2V of supply voltage respectively. For the case of 1.6V supply voltage (Figure 3.4 (a)), required voltage shifting amount for a constant transconductance is 550mV which is larger than the minimum of PMOS and NMOS, and the simulation results show ±4.97% and ±8.66% variations of overall transconductance with aspect ratios of ⁄ for PMOS source follower and ⁄ for diode connected NMOS. However, with the same aspect ratios of PMOS source follower and diode connected NMOS, Figure 3.4 (b) and (c) show that overall transconductances cannot be kept constant because required voltage shifting amount for a constant transconductance is smaller than the minimum . Using sub- threshold drain current, overall transconductance can be kept constant, but the aspect ratios of PMOS source follower would need to be ( 610 /1) and ( 910 /1) with 1.4V and 1.2V supply voltages, respectively. For diode connected NMOS, (3× 410 /1) and (3× 710 /1) of the aspect ratio are required with 1.4V and 1.2V supply voltage. Those aspect ratios are obviously impractical and the conventional and new level shifting techniques have a limited amount of voltage shifting as a result. 30 Basically, the concepts of the conventional and new level shifting technique are overlapped transition regions of the transconductances of NMOS and PMOS. With the DC voltage level shifting technique, another type of overlapped transition regions technique is also introduced in [1]. The main concept of that technique is saturation point control of current in N- and P-channel differential input pairs. This type of overlapped transition regions technique does not have a limited amount of voltage shifting. Proposed technique controls the aspect ratios of the input differential pairs transistors and the optimized aspect ratios for constant-gm are 1/5 and 1 for NMOS and PMOS respectively. As mentioned in [1], those aspect ratios are too small and degrade the noise performance and transistors mismatch insensitivity. A novel overlapped transition regions technique proposed in this chapter has the same basic concept as a previously introduced technique that controls the current saturation points of differential input pairs. We do not control the aspect ratios of differential input pairs transistors, but rather control the saturation point of a current source. Figure 3.5 shows the structure and the basic working principle of saturation point control technique with simulation results. M1 and M2 in Figure 3.5 (a) are the current source of the N-channel input pair and M2 is added to lower transconductance variation in the saturation region. In Figure 3.5 (b), without saturation point control, the saturation point of current of the N-channel input pair is indicated as . Without saturation point control, M3 is not added and is voltage of sources of the N-channel input pair. With this condition, in the turn-on region, the triode region and the saturation region of N-channel 31 (a) Structure of Saturation Point Control Technique (b) Working Principle (c) Simulation Results with 1.2V Single Supply Voltage Figure 3.5 Structure and Working Principle of Saturation Point Control Technique 32 differential input pair, the voltage of varies along with input common mode voltage (Figure 3.5 (c)). However, with saturation point control, the voltage of is lowered because of the addition of M3 (Figure 3.5 (c)) and the voltage difference between the drain and source of M2, , is lowered. As a result, a larger input common mode voltage is needed to saturate M2 and the saturation point, , is shifted to (Figure 3.5 (b)). In Figure 3.5 (c), the cut off voltage of the PMOS input pair is about 850mV of the input common mode voltage and that voltage must be the same as the shifted saturation point voltage of NMOS input pair, . For the saturation of M2 at 850mV of input common mode voltage, the voltage difference of and must be the same as . , , and are the gate-source voltage, threshold voltage, and drain-source voltage of M2 respectively. From the below equations, the value of is about 160mV at 850mV of input common mode voltage and should be 880mV. The case of the P- channel input pair is symmetric with the case of the N-channel input pair and the value of is about 360mV when there is 300mV of input common mode voltage, which is the cut off voltage of N-channel input pair. The simulation result of saturation point control is shown in Figure 3.5 (c). For this simulation, 1.2V single supply voltage is used. (Saturation of M2) ( ) ( ) 33 (a) Structure of Modified Saturation Point Control Technique (b) Simulation Results with 1.2V Single Supply Voltage (c) and Current of NMOS Pair with Modified Technique Figure 3.6 Modified Saturation Point Control Technique 34 The simulation result of Figure 3.5 (c) shows ±7.48% variation of overall transconductance and for better performance, some modification is required. Shifted saturation points, and , are well controlled, but the variation of overall transconductance in the overlapped transition regions degrade the performance. To decrease this variation, the voltage of and are modified. Figure 3.6 (a) shows the structure of modified saturation point control technique. PMOS and NMOS source followers are added to control the voltage of and , respectively. The input signal of the PMOS source follower comes from the sources of the N-channel input pair and this signal is the same as the signal of ‘ without M3’ of Figure 3.5 (c). PMOS source follower shifts this signal as much as | | of PMOS and this shifted signal is connected to . Figure 3.6 (c) shows that before modification, is constant and cannot control the current of the N-channel input pair in the transition region. of the modified technique, however, varies along with the input common mode voltage and set to 880mV at 850mV of input common mode voltage to control . Thus, in the transition region of the modified technique, and of M3 are smaller than those of the unmodified technique. As a result, because of lowered of M3, the current of N-channel input pair is lowered in the transition region and the graph of transconductance is more linear than unmodified one (Figure 3.6 (c)). The case of the P-channel input pair is symmetric with the case of the N-channel input pair. The simulation result shows that the variation of overall transconductance of the modified saturation point control technique is ±3.35% (Figure 3.6 (b)). 35 Figure 3.7 shows the simulation results of overall transconductance variation with supply voltage of 1.6V, 1.4V and 1.2V using the saturation point control technique which is the new overlapped transition regions technique proposed in this chapter. These results demonstrate that if overall transconductance is larger than the transconductance of N- or P-channel input pair in the middle range of common mode input signal, the saturation point control technique can be used generally with any supply voltage without limited amount of voltage shifting. In addition, with 1.6V supply voltage, the overall transconductance variation of the saturation point control technique is ±3.35% and better than the conventional and modified overlapped transition regions technique. Overall transconductance variations of the conventional and modified overlapped transition regions technique are ±4.97% and ±8.66%, respectively. Figure 3.7 Total Transconductance Variations with Supply Voltage of 1.6V, 1.4V, and 1.2V 36 The saturation point control technique which is novel overlapped transition regions technique is introduced to overcome the drawback of the conventional and new level shifting technique. This technique has no limitation of voltage shifting amount which is one of main drawback of the conventional and new level shifting technique. Additionally, this technique has smaller total transconductance variation than that of the conventional and new level shifting technique with the same supply voltage even though this technique is slightly complicated. 3.3 Modified New Level Shifting Technique : Hybrid of 3.1 and 3.2 New level shifting technique is introduced in Chapter 3.1 and that is the simplest technique of constant transconductance rail-to-rail op-amp for the low supply voltage environment. As mentioned in Chapter 3.1, one of the main drawbacks is relatively large total transconductance variation, ±8.66%. That is caused by the slope mismatch of transconductance in the transition regions of NMOS and PMOS input differential pairs. Because of diode connected NMOS, the saturation point of NMOS input pair’s current is shifted and that results in the gentle slope of NMOS transconductance in the transition region. In Chapter 3.2, saturation point control technique is proposed and that technique controls the saturation point of currents of NMOS and PMOS input differential pairs. Therefore, if the concept of saturation point control technique is employed for new level shifting technique, the slope mismatch of transconductance can be minimize. 37 (a) Structure of Modified New Level Shifting Technique (b) Voltage of (c) Total Transconductance Variation Figure 3.8 Structure and Working Principle of Modified New Level Shifting Technique 38 Figure 3.8 shows the structure and the working principle of modified new level shifting technique. The diode connected NMOS, M1, shifts the graph of voltage as much as of M1 and that causes the shifting of transconductance of NMOS input pair. However, in turning on region of NMOS, the slope of with M1 is gentler than that of without M1 due to the diode connected NMOS, M1 (Figure 3.8 (b)). That is the source of slope mismatch of transconductance. The saturation point control technique introduced in Chapter 3.2 employs one NMOS above the NMOS tail current source and one PMOS below the PMOS current source to control saturation points of NMOS and PMOS input pairs’ current. This concept is employed by modified new level shifting technique. In Figure 3.8 (a), M2 is added below the PMOS tail current source to control the saturation point of PMOS input pair current and the slope of PMOS transconductance is gentler than that of new level shifting technique (Figure 3.8 (c)). Figure 3.9 shows the simulation results comparison of the total transconductance variations of two techniques. New level shifting technique has ±8.66% of total transconductance variation. But, modified new level shifting technique employs the saturation point control technique and only has ±2.63% of total transconductance variation. Modified new level shifting technique does not degrade the main advantage of new level shifting technique, simplicity, and dramatically reduces the total transconductance variation from ±8.66% to ±2.63%. Modified new level shifting technique requires only two MOSFETs. One is diode connected NMOS which is used to shift the transconductance of NMOS input differential pair and another is PMOS which is employed to control the saturation point of current of PMOS input differential pair. 39 (a) Simulation Result of New Level Shifting Technique (b) Simulation Result of Modified New Level Shifting Technique Figure 3.9 Comparison of Total Transconductance Variations 40 Chapter 4. Literature Review for Extremely Low Supply Voltage Op-Amp 4.1 Extremely Low Supply Voltage Environment In Chapter 1, the total transconductance problems of low supply voltage and extremely low supply voltage environments are mentioned. As shown in Figure 1.2 and Figure 1.3, the dead zone problem of an extremely low supply voltage environment is totally different from the two-fold transconductance variation problem of a low supply voltage environment. For an extremely low supply voltage environment, some special techniques are required to increase the total transconductance of middle range of the input common mode signal to the level of the other regions of common mode input. In the dead zone of an extremely low supply voltage environment, the total transconductance is very small or almost zero. Therefore, the gain will be very small or almost zero and that is markedly different from the two-fold variation of the gain and the unity gain frequency in the low supply voltage environment. In the past years, several techniques have been proposed for an extremely low supply voltage op-amp. Some techniques use bulk of NMOS or PMOS input differential pair as a input node to avoid the dead zone, and some techniques modify or compress the input signal into the acceptable region of NMOS or PMOS input differential pair. In the following sections of 41 this chapter, four typical techniques for an extremely low supply voltage environment are explained. 4.2 Dynamic Level Shifting Technique Dynamic Level shifting Technique was first proposed in [14] and later studied in [15] ~ [17]. The basic concept of this technique is shown in Figure 4.1. Two inputs are directly connected to the resistors, R1 ~ R4. The top and bottom of resistors are connected to the variable current sources, , which currents are generated by the level shift current generator. The conceptual graph of the generated current is shown in Figure 4.1 (b). The generated current, , is controlled by the common mode input signal. When the common mode input signal is around the supply rail, ground or , the is zero and at the middle point of the common mode input signal, the reaches the maximum value. The input common mode voltages of NMOS and PMOS input pairs are given by Where and are the input common mode voltages of NMOS and PMOS input pairs, respectively, and is the original input common mode voltage. Figure 4.1 (c) shows the conceptual graph of , and . In the left half region of the figure, the input common mode voltage of PMOS input pair, , exists in the acceptable region of PMOS input pair and the input common mode voltage of NMOS input pair, 42 (a) Conceptual Input Circuit of Dynamic Level Shifting Technique (b) Current from the Level Shift Current Generator Block (c) Shifted Input Common Mode Voltage of NMOS and PMOS Input Pairs Figure 4.1 Basic Concept of Dynamic Level Shifting Technique 43 , exists in the acceptable region of NMOS input pair in the right half region. Therefore, the dead zone problem can be resolved by this technique. The main part of this technique is the level shift current generator. Figure 4.2 (a) shows the level shift current generator block. Some equations for the explanation of this block are given below. The generated current, , is current difference of and , and that is difference of and . When is larger than , is and is zero if is equal or smaller than . Thus, in the middle range of input common mode signal, both pairs are turned off which means is zero, and will be . Figure 4.2 (b) and (c) show simulation results of generated current, , and input common mode voltages of NMOS and PMOS input pairs, and . The basic concept of the dynamic level shifting technique is that the voltage shifting amount of input common mode signal is controlled by the common mode voltage. There is no voltage shifting around the supply rails, ground or , but in the 44 (a) Level Shift Current Generator Block (b) Simulation Result of Generated Current [15] (c) Simulation Result of Input Common Mode Voltage of NMOS and PMOS Input Pairs [15] Figure 4.2 Current Generator Block & Shifted Common Mode Voltages 45 middle range of the input common mode signal, the common mode voltages of NMOS and PMOS input pairs are shifted into the acceptable range of NMOS and PMOS input pairs. Thus, the dead zone problem can be avoided using this technique. In the input structure of this technique, however, two input signals of op-amp are directly connected to the resistors and this technique has finite input impedance. As mentioned in Chapter 1, one of the main requirements of the ECG amplifier is very high input impedance, almost infinity. Therefore, this technique is not suitable for the portable ECG amplifier. 4.3 Bulk Driven Input Stage Technique In [18] and [19], several types of bulk driven input stage technique are proposed. The basic concept of bulk driven input stage technique is using bulk transconductance, , rather than which is the transconductance when the gate of MOSFET is used as an input node. Usually, the gate of MOSFET is used as an input node and the voltage difference of gate and source of input MOSFET, , has to be larger than the threshold voltage, , to turn on the input MOSFET. This threshold voltage of input MOSFET makes the dead zone problem difficult to avoid for the extremely low supply voltage environment. If the bulk of input MOSFET is used as an input node, however, the input MOSFET is turned on with very small input voltage even though the input voltage is smaller than the negative supply rail. Figure 4.3 ([19]) shows the comparison of gate driven case and bulk driven case. For the gate driven case, the bulk is connected to the source of NMOS which is grounded, and for the bulk driven case, the gate of NMOS is 46 connected to . In these cases, the supply voltage range is from ground to 1.5V. When the gate is used as an input node, the input voltage should be larger than about 1V to turn on the MOSFET. But for the bulk driven case, the MOSFET is turned on in the whole range of input voltage from 0 to 1.5V. Thus, the rail-to-rail input stage can be achieved using bulk driven input technique. Figure 4.4 shows simple conceptual input structure of bulk driven input stage technique. Figure 4.3 Comparison of Gate Driven and Bulk Driven [19] Figure 4.4 Concept of Bulk Driven Input Technique 47 One of the main disadvantages of this technique is low input impedance. As mentioned in Chapter 4.2, very high input impedance is required for the portable ECG amplifier. Another disadvantage of this technique is that is usually smaller than . Thus, large body effect coefficient, γ, is required because bulk transconductance, is proportional to the body effect coefficient, γ. Because of these disadvantages, this technique is not appropriate for the portable ECG either. 4.4 Depletion Mode Input Pair Technique The depletion mode input pair technique is proposed in [20]. The depletion mode MOSFET has a physically implanted channel. Because a channel is formed intrinsically, the depletion mode MOSFET has drain current even if the voltage difference between the gate and source is zero or negative. Figure 4.5 shows the current characteristic comparison of N-channel depletion mode MOSFET and enhancement mode MOSFET. Depletion mode input pair technique employs the depletion mode MOSFETs as an input pair and has no dead zone problem because the depletion mode MOSFET has intrinsic channel and negative value of the threshold voltage, (Figure 4.6). In this technique, because the input signal is directly connected to the gate of the depletion mode input pair, the input impedance of this structure is very high, almost infinity. Using this high input impedance characteristic of depletion mode input pair technique, hybrid type of depletion mode input pair technique and bulk driven input technique is proposed in [18]. Basic concept of the input stage of this technique is shown 48 in Figure 4.7. Because the depletion mode input pair technique is employed, the input impedance of this structure is quite high, and the source of the depletion mode NMOS input differential pair is connected to the bulk of the PMOS pair. Thus, the original input signal is shifted by the depletion mode NMOS input differential pair and this shifted Figure 4.5 Current Characteristic Comparison Figure 4.6 Concept of Depletion Mode Input Pair Technique 49 input signal is fed to the bulk of the PMOS pair which is the input pair of bulk driven input technique. Depletion mode input pair technique overcomes the dead zone problem of the extremely low supply voltage environment with very high input impedance. However, the depletion mode MOSFET cannot be fabricated by the standard CMOS processes ([21]) and requires extra costs and processes. That is the main disadvantage of this technique. 4.5 Input Signal Compression Technique Another technique to overcome dead zone problem of the extremely low supply voltage environment is input signal compression technique proposed in [21 and 22].The Figure 4.7 Hybrid Type of Depletion Mode Input and Bulk Driven Input Techniques 50 basic concept of this technique is that the rail-to-rail input common mode signal is compressed by the input signal compression block indicated as block ‘a’ in Figure 4.8 into the acceptable range of PMOS input pair of op-amp. Because this technique employs the PMOS pair input stage, not the complementary differential input structure, and the original input signal is compressed into the acceptable range of PMOS input pair, the dead zone problem can be avoided. Figure 4.8 shows the basic concept of this technique. Figure 4.9 (a) shows the inside of block ‘a’, which is composed of 3 sub blocks. The input/output voltage characteristics of each block are shown in Figure 4.9 (b), (c) and (d). Block 1 consists of a PMOS source follower in the first stage, a NMOS source follower in the second stage, and a PMOS source follower in the last stage (Figure 4.9 (b)). This cascade of source followers shifts the input signal and the output voltage of block 1, , is shown in the graph. The first and the second stage of block 2 are a NMOS and a PMOS source follower, respectively (Figure 4.9 (c)). At the last stage of block 2, the output voltage Figure 4.8 Basic Concept of Input Signal Compression Technique 51 (a) Input Signal Compression Block (b) Working Principle of Block 1 (c) Working Principle of Block 2 (d) Working Principle of Block 3 Figure 4.9 Basic Concept of Input Signal Compression Technique 52 is constant for low because of source follower operation of the last stage of block 2, while that works as a common-source amplifier which inverts voltage for high . Figure 4.9 (c) shows the overall behavior of block 2. Two inputs of block 3 are and . is the output of block 3 as well as the whole block of signal compression, block ‘a’ (Figure 4.9 (d)). When is low, is constant and block 3 operates as a NMOS source follower. On the other hand, when is high, is constant and block 3 inverts the signal of . The rail-to-rail input signal is compressed as through block ‘a’, input signal compression block. Using this concept of input signal compression, the dead zone problem of the extremely low supply voltage environment can be avoided. This input signal compression technique, however, has some drawbacks. First, the signal compression block, block ‘a’, is very complex and second, this technique has reduced bandwidth as mentioned in [22]. The third one is signal to noise ratio, SNR. In input signal compression technique, the original input signal is compressed by the signal compression block and this compressed input signal is fed to the PMOS input pair op-amp. The compressed differential input signal is obviously smaller than the original differential input signal. Therefore, the SNR of input signal compression technique is worse than that of other techniques which use the original differential input signal. 53 Chapter 5. Novel Extremely Low Supply Voltage Rail-to-Rail Op-Amps 5.1 Common Mode Elimination Technique In Chapter 4.5, the input signal compression technique is briefly explained. Even if that technique has some drawbacks, the input signal compression technique does avoid the dead zone problem of the extremely low supply voltage. This technique works very well in the extremely low supply voltage environment, but we cannot achieve additional CMRR advantage from that technique, and has been stated before, portable ECG amplifiers require very high CMRR because of common mode noise from other muscles of human body. In this chapter, a novel common mode elimination technique for the extremely low supply voltage environment is proposed using the basic concept of input signal compression technique. In Figure 5.1, the basic concept of novel common mode elimination technique is shown. Block ‘a’ is the signal compression block of input signal compression technique explained in Chapter 4.5. Using signal inverting block, named block ‘b’, and resistors, common mode input signal from 0 to 1V can be kept constant. While differential input signal is extracted and transferred to the following conventional PMOS input differential amplifier. The compressed input signal which is the output signal of block ‘a’ is inverted by block ‘b’ and using the ratio of two resistors, rail-to-rail 54 variation of the input common mode signal is fixed at the crossing point of and which are the output signal of block ‘a’ and ‘b’ respectively. While differential input signal is still ‘alive’ and transferred to the following amplifier because and are cross connected when they are connected to resistors (Figure 5.2 and Figure 5.3). Figure 5.1 Structure of Common Mode Elimination Technique (a) Signal Inverting Block, Block ‘b’ (b) Common Mode Elimination Block Followed by Op-Amp and Simulation Result Figure 5.2 Basic Concept of Common Mode Elimination 55 Figure 5.4 shows the simulation results of minimum CMRR of input signal compression and common mode elimination technique. For input signal compression technique, rail-to-rail signal variation, 0 to 1V, compressed from 72.6mV to 449.4mV (a) Basic Concept of Differential Input Signal Extraction (b) Simulation Result of Differential Input Signal Extraction Figure 5.3 Differential Input Signal Extraction 56 and that means 62.32% of compression rate for common mode and differential signal. For the common mode elimination technique, the differential signal is compressed by about 71.4% as shown in Figure 5.2 (e). Because of the compressed differential signal, the common mode elimination technique has some loss of gain, but because of eliminated common mode signal, high CMRR has been obtained. However, even if this technique has ultra-high CMRR using common mode elimination technique, the original disadvantages of the input signal compression technique are not resolved. This common mode elimination technique still employs a complex input signal compression block, block ‘a’, and has a reduced bandwidth. In addition, the signal to noise ratio, SNR, of common mode elimination technique is worse than that of input signal compression technique. Because the compression rate of common mode elimination technique is higher than that of input signal compression technique, the compressed differential input signal which is fed to the PMOS input pair op-amp of common mode elimination technique is smaller than that of the input signal compression technique. So, a novel technique for the extremely low supply voltage Figure 5.4 Comparison of Minimum CMRR 57 environment is proposed in the following section to resolve these drawbacks of input signal compression and common mode elimination techniques. 5.2 New Input Signal Compression Technique As mentioned in Chapter 4.5 and 5.1, input signal compression technique and common mode elimination technique have some disadvantages and modified technique which is more appropriate for the portable ECG system is required to overcome those disadvantages. In this chapter, new input signal compression technique which is the modified version of input signal compression and common mode elimination techniques is proposed to overcome some drawbacks of the previous techniques. Both the input signal compression technique and the common mode elimination technique employ a conventional PMOS input because the compressed input signal and common mode eliminated signal are located in the acceptable common mode range of PMOS input pair. For a novel input signal compression technique, however, the complementary differential input pair structure is employed. Figure 5.5 shows the structure of proposed novel input signal compression technique. For common mode input signal technique, only one common mode elimination block which is composed of 2 blocks of ‘a’, 2 blocks of ‘b’, and 4 resistors is required for the PMOS input pair op-amp. For a novel input signal compression technique, however, one more common mode elimination block is required for the complementary differential input pair op-amp which has both PMOS and NMOS input pairs. 58 Figure 5.6 shows working principle and the structure of block ‘1’ which is composed of block ‘a1’, ‘b1’, and 4 resistors for PMOS input pair. The block a1 is a simple input signal compression block which is a NMOS source follower, not the complex input signal compression block which is employed in input signal compression and common mode elimination techniques, and the block b1 is a signal inverting block which is very similar with that of the common mode elimination technique. In region I, the block a1 is turned off and differential input signal is not transferred to the PMOS input pair. The block a1 is turned on in region II and III, but the transferred differential input signal of region II is smaller than that of region III because in region II, the NMOS source follower of the block a1 is in triode region and signal compression rate is higher than that of region III. This differential signal loss will be compensated by the signal from the block ‘2’ which is connected to the NMOS input pair. Figure 5.5 Structure of New Input Signal Compression Technique 59 The structure and working principle of the block ‘2’ which is similar to the block ‘1’ is shown in Figure 5.7. The block a2 is an input signal compression block which is a simple PMOS source follower and the block b2 is a signal inverting block. In region I, only compressed differential input signal of the block ‘2’ is transferred to NMOS input pair because the block a1 is turned off and no differential input signal from the block ‘1’ is transferred to PMOS input pair. In region II, compressed differential input signal of the block ‘2’ which is smaller than that of region I compensate the compressed differential Figure 5.6 Structure and Working Principle of Block ‘1’ 60 input signal of the block ‘1’. The block a2 is turned off in region III and no differential signal is transferred. The differential input signal transfer and compensation concept is shown in Figure 5.8. For this technique, the common mode elimination technique is employed and the common mode variation of ⁄ and ⁄ is below 2mV. Thus, the transconductance variation of PMOS and NMOS input pair is almost ‘0’. But, because of compression rate difference among those regions, the gain variation at the output still Figure 5.7 Structure and Working Principle of Block ‘2’ 61 exists. However, input signal compression technique and common mode elimination technique also have gain variation because of nonlinearity of compressed input signal. The overall gain variation of a novel technique is smaller than that of input signal compression technique and common mode elimination technique. Figure 5.9 shows the gain and unity gain frequency comparisons of simulation results of 3 techniques, input signal compression technique, common mode elimination technique, and a proposed novel input signal compression technique. The unity gain frequencies of previously proposed techniques, input signal compression and common Figure 5.8 Concept of Differential Signal Extraction and Compensation Figure 5.9 Comparisons of Gain and Unity Gain Frequency 62 mode elimination techniques, are below 30KHz and that of a proposed novel technique expands to 1.746MHz. A novel input signal compression technique proposed in this chapter overcomes some disadvantages of previously introduced techniques. First, the complex input signal compression blocks of input signal compression and common mode elimination techniques are replaced to the simple NMOS and PMOS source followers. Second, the unity gain frequency expands to 1.746MHz. Previously introduced techniques have reduced bandwidths and unity gain frequencies of those techniques are below 30KHz. For the last part, new input signal compression technique has better SNR than previous techniques. As mentioned in Chapter 5.1, the signal compression rate of input signal compression and common mode elimination techniques are about 63% and 71% respectively. That means if the original differential input signal is 1mV of peak-to-peak value, the compressed and common mode eliminated differential input signal of those techniques are 0.37mV and 0.29mV respectively. However, the signal compression rate of proposed novel input signal compression technique is 50% and 0.5mV peak-to-peak compressed differential input signal is transferred to the op-amp when the original peak- Figure 5.10 Comparison of Transferred Differential Input Signal 63 to-peak value of differential input signal is 1mV (Figure 5.10). Because bigger differential input signal is transferred, proposed technique has better signal to noise ratio than previous techniques. 64 Chapter 6. Simulation Results and Comparison In this chapter, all simulation results and comparisons of five novel rail-to-rail op- amp techniques are described. Large transistor sizes are used to reduce noise as these designs, especially the input signal compression designs, can have substantial noise. As mentioned in Chapter 1.2, the target input referred noise level is about 5µV/√ at 1Hz. All rail-to-rail op-amp techniques proposed in this dissertation, except the common mode elimination technique, have acceptable input referred noise due to using large transistors. The common mode elimination technique, however, has limited bandwidth and poor SNR characteristic. Reducing noise by using large transistors is not appropriate for this technique because of the bandwidth problem. Therefore, only schematic simulation results without noise reduction will be given for the common mode elimination technique. 6.1 Simulation Results of New Level Shifting Technique Figure 6.1 shows the overall structure comparison of the conventional level shifting technique and the new level shifting technique. As mentioned in Chapter 3.1, the new level shifting technique employs only one diode connected MOSFET while four resistors are required for the conventional level shifting technique. In Figure 3.3, the comparison of overall 65 transconductance variation is shown and the overall variation of new level shifting technique, ±8.66%, is higher than that of the traditional level shifting technique, ±4.97%. Because of this overall transconductance variation, the op-amp has gain variation over the entire rail-to-rail input common mode range. Figure 6.2 (a) shows the gain variation comparison of the conventional level shifting technique and new level shifting technique. The new level shifting technique has larger gain variation (±1.3dB) than the conventional level shifting technique (±1.215dB) because (a) Conventional Level Shifting Technique (b) New Level Shifting Technique Figure 6.1 Overall Structure Comparison 66 of the larger overall transconductance variation. The unity gain frequencies of the conventional and new level shifting technique are 1.1MHz and 1.25MHz respectively. The phase margins of the conventional and new level shifting technique are 62.3º and 58.9º (Figure 6.2 (b)). Table 6.1 shows the comparisons of all simulation results of those two techniques. The minimum CMRR of the conventional and new level shifting technique are 80dB and 73.29dB. From Table 6.1, the new level shifting technique has lower power consumption than the conventional level shifting technique, as the conventional level shifting technique requires additional current for (a) Comparison of Gain Variation (b) Comparison of Phase Margin Figure 6.2 Comparison of Conventional and New Level Shifting Technique 67 two PMOS source followers which shift input common mode signal for PMOS differential input pair. However, PMOS source followers are not required for new level shifting technique. Therefore, no additional currents are required and power consumption of the new level shifting technique is lower than that of the conventional level shifting technique. The new level shifting technique is modified to reduce input referred noise. For the ECG amplifier, the frequency of input signal is very low, below 150Hz, and the flicker noise is dominant in this frequency range. Cadence SPECTRE simulator and TSMC 0.25-µm technology are used for this simulation and from [23], equation for flicker noise model used in SPECTRE simulator is given below. Conventional Level Shifting Technique New Level Shifting Technique Supply Voltage 1.6V 1.6V ICMR Rail-to-Rail Rail-to-Rail Gm Variation ±4.97% ±8.66% Avg. Gain 76.145dB 77.08dB Gain Variation ±1.215dB ±1.3dB Unity Gain Freq. 1.1MHz 1.25MHz Phase Margin 62.3º 58.9º CMRR ≥ 80dB ≥ 73.29dB Avg. Power Consumption (@150Hz) 89.48µW 79.14µW Table 6.1 Simulation Results of Conventional and New Level Shifting Techniques 68 is the drain noise current spectral density and , , , are frequency, oxide capacitance, effective gate width and length of MOSFET respectively. , , and are flicker noise coefficient, flicker noise exponent, and flicker noise frequency coefficient respectively. From the above equation, larger transistor has lower flicker noise. For the flicker noise reduction of new level shifting rail-to-rail op-amp, 25 times larger transistors than the original schematic transistors are used for the complementary input differential stage and the folded cascode current summing stage. Figure 6.3 shows the input referred noise comparison of before and after noise reduction. Before noise reduction, the average input referred noise is about 120µV/√ at 1Hz. As mentioned in Chapter 1.2, the target noise level for this work is 5µV/√ at 1Hz and after noise reduction, the average input referred noise is about 5.2µV/√ at 1Hz. This flicker noise reduction method using large transistors, however, has a main drawback which is reduced bandwidth. To reduce flicker noise, large transistors for the Figure 6.3 Input Referred Noise of New Level Shifting Technique 69 complementary input differential pairs are employed and because of these large input transistors, the bandwidth of op-amp is reduced. Figure 6.4 shows the simulation results comparisons of before and after noise reduction. Before noise reduction, the unity gain frequency of new level shifting technique is 1.25MHz but after noise reduction, the unity gain frequency is decreased to 340.5KHz. Because of the reduced bandwidth, gain has to be lowered from 77.08dB to 66.775dB for the 3-dB frequency of 150Hz which is the upper frequency range of the ECG amplifier. Table 6.2 shows the simulation results comparisons of before and after noise reduction. The main differences are noise, gain, (a) Comparison of Gain and Unity Gain Frequency (b) Comparison of Phase Margin Figure 6.4 Simulation Results Comparisons of Before and After Noise Reduction 70 Before Noise Reduction After Noise Reduction Supply Voltage 1.6V 1.6V ICMR Rail-to-Rail Rail-to-Rail Avg. Gain 77.08dB 66.775dB Gain Variation ±1.3dB ±0.725dB Unity Gain Freq. 1.25MHz 340.5KHz Phase Margin 58.9º 59.2º CMRR ≥ 73.29dB ≥ 65.28dB Avg. Power Consumption (@150Hz) 79.14µW 82.2µW Input Referred Noise (@1Hz) 120µV/√ 5.2µV/√ Table 6.2 Simulation Results Comparison of Before and After Noise Reduction Figure 6.5 Layout Picture of New Level Shifting Technique (125.82µm×93.18µm) PMOS Input Pair & Current Source Diode Connected NMOS Output Stage NMOS Input Pair & Current Source Folded Cascode Current Summing Stage 71 (a) Comparison of Gain and Unity Gain Frequency (b) Comparison of Phase Margin (c) Comparison of Noise Figure 6.6 Comparisons of Schematic and Post Layout Simulations 72 gain variation, and bandwidth. The other simulation results are almost same with the results without noise reduction. Figure 6.5 shows the layout picture of new level shifting technique and post layout simulation results are compared with schematic simulation results in Figure 6.6. Table 6.3 shows the comparison of post layout simulation and schematic simulation results. The post layout simulation results are almost same with the schematic simulation results with noise reduction. 6.2 Simulation Results of Saturation Point Control Technique The overall structure of the saturation point control technique rail-to-rail constant transconductance op-amp is shown in Figure 6.7. As mentioned in Chapter 6.1, large transistors are employed to reduce input referred noise and simulation results Schematic Simulation Post Layout Simulation Supply Voltage 1.6V 1.6V ICMR Rail-to-Rail Rail-to-Rail Avg. Gain 66.775dB 66.98dB Gain Variation ±0.725dB ±0.76dB Unity Gain Freq. 340.5KHz 374KHz Phase Margin 59.2º 59.8º CMRR ≥ 65.28dB ≥ 65.33dB Avg. Power Consumption (@150Hz) 82.2µW 84.7µW Input Referred Noise (@1Hz) 5.2µV/√ 5.3µV/√ Table 6.3 Comparison of Schematic and Post Layout Simulation Results 73 comparisons of before and after noise reduction are shown in Figure 6.8. 25 times larger transistors than the schematic transistors without noise reduction are used for the complementary input differential stage and the folded cascode current summing stage. Because of large transistors of input differential pairs, the unity gain frequency is reduced from 1MHz to 275.2KHz and the gain is decreased from 75.33dB to 67.825dB. Before noise reduction, the input referred noise at 1Hz is about 120µV/√ . The input referred noise at 1Hz after noise reduction is decreased to 5.02µV/√ . Table 6.4 shows the simulation results comparison of before and after noise reduction. The layout of the saturation point control technique op-amp is shown in Figure 6.9. Comparisons of schematic simulation results with noise reduction and post layout simulation results are shown in Figure 6.10 and Table 6.5. As shown in these results, the post layout simulation results are almost same with reduced noise schematic simulation results. Figure 6.7 Overall Structure of Saturation Point Control Technique 74 (a) Comparison of Gain and Unity Gain Frequency (b) Comparison of Phase Margin (c) Comparison of Input Referred Noise Figure 6.8 Simulation Results Comparisons of Before and After Noise Reduction 75 Before Noise Reduction After Noise Reduction Supply Voltage 1.2V 1.2V ICMR Rail-to-Rail Rail-to-Rail Avg. Gain 75.33dB 67.825dB Gain Variation ±0.39dB ±0.185dB Unity Gain Freq. 1MHz 275.2KHz Phase Margin 61.2º 58.1º CMRR ≥ 80.71dB ≥ 66.98dB Avg. Power Consumption (@150Hz) 57.64µW 62.47µW Input Referred Noise (@1Hz) 120µV/√ 5.02µV/√ Table 6.4 Simulation Results Comparison of Before and After Noise Reduction Figure 6.9 Layout of Saturation Point Control Technique (118.38µm×83.1µm) PMOS Saturation Control NMOS Saturation Control PMOS Input Pair & Current Source NMOS Input Pair & Current Source Output Stage Folded Cascode Current Summing Stage 76 (a) Comparison of Gain and Unity Gain Frequency (b) Comparison of Phase Margin (c) Comparison of Input Referred Noise Figure 6.10 Comparisons of Schematic and Post Layout Simulations 77 6.3 Simulation Results of Modified New Level Shifting Technique The whole structure of the modified new level shifting technique is compared with the structure of new level shifting technique in Figure 6.11. As mentioned in Chapter 3.3, in a modified new level shifting technique, one PMOS is added below current source of PMOS input pair to control saturation point of current of PMOS input pair while new level shifting technique requires only one diode connected NMOS above current source of NMOS input pair. Because of this PMOS saturation point controller, the overall transconductance variation of the modified new level shifting technique is smaller than that of the new level shifting technique (Figure 3.9) and as a result, the modified Schematic Simulation Post Layout Simulation Supply Voltage 1.2V 1.2V ICMR Rail-to-Rail Rail-to-Rail Avg. Gain 67.825dB 68.03dB Gain Variation ±0.185dB ±0.38dB Unity Gain Freq. 275.2KHz 301KHz Phase Margin 58.1º 57.4º CMRR ≥ 66.98dB ≥ 67.73dB Avg. Power Consumption (@150Hz) 62.47µW 64.83µW Input Referred Noise (@1Hz) 5.02µV/√ 5.13µV/√ Table 6.5 Comparison of Schematic and Post Layout Simulation Results 78 new level shifting technique has only ±0.245dB of gain variation at the output while the gain variation of the new level shifting technique is ±0.725dB (Table 6.6). The schematic simulation results comparisons of new level shifting and modified new level shifting techniques with noise reduction are given in Table 6.6, Figure 6.12 and Figure 6.13. (a) New Level Shifting Technique (b) Modified New Level Shifting Technique Figure 6.11 Overall Structure Comparison of New and Modified New Level Shifting Technique 79 New Level Shifting Modified New level Shifting Supply Voltage 1.6V 1.6V ICMR Rail-to-Rail Rail-to-Rail Avg. Gain 66.775dB 67.005dB Gain Variation ±0.725dB ±0.245dB Unity Gain Freq. 340.5KHz 356.5KHz Phase Margin 59.2º 60.1º CMRR ≥ 65.28dB ≥ 74.59dB Avg. Power Consumption (@150Hz) 82.2µW 81.7µW Input Referred Noise (@1Hz) 5.2µV/√ 5.16µV/√ Table 6.6 Schematic Simulation Results Comparison of Two Techniques (a) Gain Variation and Unity Gain Frequency Comparison (b) Phase Margin Comparison Figure 6.12 Schematic Simulation Results Comparison of Two Techniques 80 The layout picture of the modified new level shifting technique is shown in Figure 6.14 and post layout simulation results comparisons are given in Figure 6.15 and Table 6.7. The post layout simulation results of modified new level shifting technique are almost same with reduced noise schematic simulation results. Figure 6.13 Input Referred Noise Comparison of Two Techniques Figure 6.14 Layout Picture of Modified New Level Shifting Technique (128.7µm×93.18µm) NMOS Input Pair & Current Source PMOS Saturation Control PMOS Input Pair & Current Source Diode Connected NMOS Output Stage Folded Cascode Current Summing Stage 81 (a) Comparison of Gain and Unity Gain Frequency (b) Comparison of Phase Margin (c) Comparison of Noise Figure 6.15 Post Layout Simulation Results Comparison of Two Techniques 82 Table 6.8 shows the overall simulation results comparing the three novel techniques for the low supply voltage environment. The new level shifting technique is New Level Shifting Modified New Level Shifting Supply Voltage 1.6V 1.6V ICMR Rail-to-Rail Rail-to-Rail Avg. Gain 66.98dB 67.175dB Gain Variation ±0.76dB ±0.345dB Unity Gain Freq. 374KHz 376KHz Phase Margin 59.8º 59.5º CMRR ≥ 65.33dB ≥ 74.8dB Avg. Power Consumption (@150Hz) 84.7µW 82.9µW Input Referred Noise (@1Hz) 5.3µV/√ 5.225µV/√ Table 6.7 Post Layout Simulation Results Comparison of Two Techniques New Level Shifting Saturation Point Control Modified New Level Shifting Supply Voltage 1.6V 1.2V 1.6V ICMR Rail-to-Rail Rail-to-Rail Rail-to-Rail Avg. Gain 66.98dB 68.03dB 67.175dB Gain Variation ±0.76dB ±0.38dB ±0.345dB Unity Gain Freq. 374KHz 301KHz 376KHz Phase Margin 59.8º 57.4º 59.5º CMRR ≥ 65.33dB ≥ 67.73dB ≥ 74.8dB Avg. Power Consumption (@150Hz) 84.7µW 64.83µW 82.9µW Input Referred Noise (@1Hz) 5.3µV/√ 5.13µV/√ 5.225µV/√ Table 6.8 Overall Simulation Results Comparison of Low Supply Voltage Techniques 83 the simplest technique for the low supply voltage environment but this technique has the largest transconductance variation among those three novel techniques. That causes the largest gain variation in Table 6.8. the saturation point control technique does not have a limitation of a set voltage shifting amount which is one of main drawbacks of new level shifting and modified new level shifting techniques, and has the lowest supply voltage. That causes the lowest average power consumption. However, saturation point control technique is more complex than new level shifting and modified new level shifting techniques. Modified new level shifting technique is very simple and has the smallest transconductance and gain variations. But this technique still has limited amount of voltage shifting. 6.4 Simulation Results of Common Mode Elimination Technique As mentioned in Chapter 5.1, the common mode elimination technique is a modification of the input signal compression technique. Figure 6.16 compares the whole circuit of the input signal compression and common mode elimination techniques. For common mode elimination technique, additional two signal inverting blocks and four resistors are required to eliminate common mode input signal. Figure 5.4 shows that ultra-high CMRR can be achieved using common mode elimination technique. The common mode variation of common mode eliminated input signal, ⁄ , is smaller than 2mV when the original common mode input signal, ⁄ , varies from 0 to 1V. Therefore, the overall transconductance variation of PMOS input differential pair of 84 common mode elimination technique is almost zero. From the cases of previous three novel techniques for the low supply voltage environment, the gain variation is directly proportional to the overall transconductance variation (Table 6.8). For the cases of input signal compression and common mode elimination techniques for the extremely low supply voltage environment, however, relatively large gain variations are achieved even though the overall transconductance variations are very small or almost zero as shown in Figure 6.17. That is caused by non-linearity of the compressed input signal. As shown in (a) Input Signal Compression Technique (b) Common Mode Elimination Technique Figure 6.16 Overall Structure Comparison of Input signal Compression Technique and Common Mode Elimination Technique 85 Figure 4.9 and Figure 5.2, the compressed input signals of input signal compression and common mode elimination techniques are not perfectly linear. Thus, the differential input signal is not transferred uniformly according to the changing of common mode input signal and this un-uniform differential input signal is the main source of gain variation. Figure 6.17 and Table 6.9 shows the schematic simulation results comparison without noise reduction. (a) Comparison of Gain and Unity Gain Frequency (b) Comparison of Phase Margin Figure 6.17 Schematic Simulation Results Comparison of Two Techniques 86 In Chapter 6.1, 6.2 and 6.3, simulation results of three novel techniques for the low supply voltage environment are shown and unity gain frequencies of those techniques are about 1MHz without noise reduction. As mentioned in Chapter 6.1, after noise reduction, the bandwidth of op-amp is reduced because of large transistors of input differential pairs and the unity gain frequencies of three novel techniques are reduced to several hundreds of KHz. As shown in Figure 6.17 and Table 6.9, input signal compression technique and common mode elimination technique has reduced bandwidth and the unity gain frequency of common mode elimination technique is 12.63KHz. If large transistors are used to reduce input referred noise, this technique will have more reduced bandwidth and that is not suitable for the ECG system. Another drawback of common mode elimination technique is degradation of SNR as mentioned in Chapter 5.1. Input Signal Compression Common Mode Elimination Supply Voltage 1V 1V ICMR Rail-to-Rail Rail-to-Rail CM Compression Rate 62.32% 99.63% DM Compression Rate 62.32% 71.4% Avg. Gain 45.455dB 43.295dB Gain Variation ±0.985dB ±1.075dB Unity Gain Freq. 26.9KHz 12.63KHz Phase Margin 58.1º 57.3º CMRR ≥ 56.26dB ≥ 115.1dB Avg. Power Consumption (@150Hz) 38.875µW 40.39µW Table 6.9 Schematic Simulation Results Comparison of Two Techniques 87 The higher compression rate means smaller differential input signal and this smaller signal reduces the SNR. In Table 6.9, the differential input signal compression rate of the input signal compression technique is 62.32% and that of common mode elimination technique is 71.4%. Therefore, the SNR of the common mode elimination technique is worse than that of the input signal compression technique. Because of these reasons, another technique is required for the portable ECG system and new input signal compression technique is introduced. 6.5 Simulation Results of New Input Signal Compression Technique Figure 6.18 shows the overall structure of the new input signal compression technique. As mentioned in Chapter 5.2, the block ‘a1’ and ‘a2’ are simple source followers rather than the complex input signal compression block which is the block ‘a’ of input signal compression technique and common mode elimination technique. The block ‘b1’ and ‘b2’ are simple signal inverting block and similar with the block ‘b’ of common mode elimination block. Another main difference between the new input signal compression technique and two techniques shown in Figure 6.16 which are input signal compression and common mode elimination techniques is the structure of input differential pair. Conventional PMOS input differential pair is employed in input signal compression technique and common mode elimination technique (Figure 6.16). New input signal compression technique, however, employs complementary input differential pair structure which are commonly used for low supply voltage environment. The 88 schematic simulation results comparisons without noise reduction are shown in Figure 6.19 and Table 6.10. As mentioned in Chapter 5.2, the band width of new input signal compression technique with simple signal compression block is much larger than that of input signal compression technique or common mode elimination technique. The unity gain frequency of new input signal compression technique is 1.736MHz while 26.9KHz and 12.63KHz are the unity gain frequencies of the other techniques. As mentioned in Chapter 6.4, the gain variations of input signal compression technique and common mode elimination technique are not caused by overall transconductance variation but rather Figure 6.18 Overall Structure of New Input Signal Compression Technique 89 caused by non-linearity of compressed input signal. New input signal compression technique still has gain variation caused by non-linearity of compressed input signal, but the gain variation of new level shifting technique is much smaller than that of input signal compression technique and common mode elimination technique (Table 6.10). It is worth noting that the differential signal compression rate of new input signal compression technique is smaller than that of input signal compression technique or common mode elimination technique. The smaller differential signal compression rate means that the (a) Comparison of Gain and Unity Gain Frequency (b) Comparison of Phase Margin Figure 6.19 Schematic Simulation Results Comparison of Three Techniques 90 larger differential signal can be transferred to the next stage. Therefore, the gain of new input signal compression technique is much larger than that of two techniques. The noise of new input signal compression technique is reduced using large transistors of input differential pairs and folded cascode current summing stage. The schematic simulation results comparisons are given in Figure 6.20 and Table 6.11. Because of the noise reduction with large transistors, 1.736MHz of unity gain frequency of new input signal compression technique (Figure 6.19) is reduced to 103.2KHz (Figure 6.20 and Table 6.11). Even though the unity gain frequency of new input signal compression technique is reduced due to the noise reduction, reduced unity gain frequency, 103.2KHz, is larger than that of input signal compression technique, 26.9KHz, Input Signal Compression Common Mode Elimination New Input Signal Compression Supply Voltage 1V 1V 1V ICMR Rail-to-Rail Rail-to-Rail Rail-to-Rail CM Compression Rate 62.32% 99.63% 93.2% DM Compression Rate 62.32% 71.4% 50% Avg. Gain 45.455dB 43.295dB 66.575dB Gain Variation ±0.985dB ±1.075dB ±0.455dB Unity Gain Freq. 26.9KHz 12.63KHz 1.736MHz Phase Margin 58.1º 57.3º 58.1º CMRR ≥ 56.26dB ≥ 115.1dB ≥ 83.2dB Avg. Power Consumption (@150Hz) 38.875µW 40.39µW 69.74µW Table 6.10 Schematic Simulation Results Comparison of Three Techniques 91 (a) Comparison of Gain and Unity Gain Frequency (b) Comparison of Phase Margin (c) Comparison of Noise Figure 6.20 Schematic Simulation Results Comparison of Before and After Noise Reduction 92 or common mode elimination technique, 12.63KHz, without noise reduction. And the gain of new input signal compression technique is still much larger than that of the other techniques. The layout picture of new input signal compression technique is shown in Figure 6.21. The comparisons of schematic simulation results with noise reduction and post layout simulation results of new input signal compression technique are given in Figure 6.22 and Table 6.12. All the results of post layout simulation are almost same with the schematic simulation results. As mentioned in Chapter 5.1 and 5.2, if the original input signal is compressed, the SNR of overall system is degraded because the compressed signal is transferred to the op-amp while the noise of op-amp is not changed. Even though the compression rate of new input signal compression technique is smaller than that of Before Noise Reduction After Noise Reduction Supply Voltage 1V 1V ICMR Rail-to-Rail Rail-to-Rail Avg. Gain 66.575dB 61.255dB Gain Variation ±0.455dB ±0.675dB Unity Gain Freq. 1.736MHz 103.2KHz Phase Margin 58.1º 57.8º CMRR ≥ 83.2dB ≥ 84.83dB Avg. Power Consumption (@150Hz) 69.74µW 68.23µW Input Referred Noise (@1Hz) 372µV/√ 8.3µV/√ Table 6.11 Schematic Simulation Results Comparison of New input Signal Compression Technique 93 input signal compression technique or common mode elimination technique, the original input signal is compressed in new input signal compression technique and the SNR is degraded. And the input referred noise levels of novel three techniques for the low supply voltage environment, new level shifting, saturation point control, and modified new level shifting techniques, without noise reduction are about 120µV/√ at 1Hz. The input referred noise of new input signal compression technique without noise reduction is 372µV/√ at 1Hz. For these reasons, the transistors of reduced noise new input signal compression technique op-amp are 40 times larger than the transistors without noise reduction while 25 times larger transistors are employed for novel three techniques, new level shifting, saturation point control, and modified new level shifting techniques. In Figure 6.22 and Table 6.12, the input referred noise of new input signal compression Figure 6.21 Layout Picture of New Input Signal Compression Technique (207.78µm×119.46µm) Block a2 Block a2 Block b2 Block b2 Block b1 Block b1 Block a1 Block a1 PMOS Input Pair & Current Source NMOS Input Pair & Current Source Output Stage Folded Cascode Current Summing Stage 94 (a) Comparison of Gain and Unity Gain Frequency (b) Comparison of Phase Margin (c) Comparison of Noise Figure 6.22 Comparison of Schematic and Post Layout Simulation Results 95 technique is 8.9uV/√ at 1Hz. That is slightly larger than the input referred noises of novel three techniques for the low supply voltage environment, but 8.9uV/√ at 1Hz is still lower than the typical noise from the electrode of ECG which is about 10uV/√ at 1Hz [24]. The schematic simulation results comparisons without noise reduction of all five novel techniques proposed in this dissertation are given in Table 6.13. Table 6.14 shows the post layout simulation results comparisons of four novel techniques. New level shifting technique, saturation point control technique, and modified new level shifting technique are novel rail-to-rail op-amp techniques for the low supply voltage environment and new input signal compression technique is a novel technique for the extremely low supply voltage environment. Schematic Simulation Results Post Layout Simulation Results Supply Voltage 1V 1V ICMR Rail-to-Rail Rail-to-Rail Avg. Gain 61.255dB 60.715dB Gain Variation ±0.675dB ±0.665dB Unity Gain Freq. 103.2KHz 102.7KHz Phase Margin 57.8º 57.6º CMRR ≥ 84.83dB ≥ 82.97dB Avg. Power Consumption (@150Hz) 68.23µW 70.02µW Input Referred Noise (@1Hz) 8.3µV/√ 8.9µV/√ Table 6.12 Comparison of Schematic and Post Layout Simulation Results 96 New Level Shifting Saturation Point Control Modified New Level Shifting Common Mode Elimination New Input Signal Compression Supply Voltage 1.6V 1.2V 1.6V 1V 1V ICMR Rail-to-Rail Rail-to-Rail Rail-to-Rail Rail-to-Rail Rail-to-Rail Avg. Gain 77.08dB 75.33dB 77.67dB 43.295dB 66.575dB Gain Variation ±1.3dB ±0.39dB ±0.24dB ±1.075dB ±0.455dB Unity Gain Freq. 1.25MHz 1MHz 1.3MHz 12.63KHz 1.736MHz Phase Margin 58.9º 61.2º 60.72º 57.3º 58.1º CMRR ≥ 73.29dB ≥ 80.71dB ≥ 82.74dB ≥ 115.1dB ≥ 83.2dB Avg. Power Consumption (@150Hz) 79.14µW 57.64µW 80.2µW 40.39µW 69.74µW Table 6.13 Schematic Simulation Results Comparison of All Five Novel Techniques without Noise Reduction New Level Shifting Saturation Point Control Modified New Level Shifting New Input Signal Compression Supply Voltage 1.6V 1.2V 1.6V 1V ICMR Rail-to-Rail Rail-to-Rail Rail-to-Rail Rail-to-Rail Avg. Gain 66.98dB 68.03dB 67.175dB 60.715dB Gain Variation ±0.76dB ±0.38dB ±0.345dB ±0.665dB Unity Gain Freq. 374KHz 301KHz 376KHz 102.7KHz Phase Margin 59.8º 57.4º 59.5º 57.6º CMRR ≥ 65.33dB ≥ 67.73dB ≥ 74.8dB ≥ 82.97dB Avg. Power Consumption (@150Hz) 84.7µW 64.83µW 82.9µW 70.02µW Input Referred Noise (@1Hz) 5.3µV/√ 5.13µV/√ 5.225µV/√ 8.9µV/√ Table 6.14 Post Layout Simulation Results Comparison of Four Novel Techniques 97 The new level shifting technique is the simplest technique among the novel rail- to-rail op-amp techniques proposed in this dissertation. However, this technique has the worst gain variation and average power consumption. Saturation point control technique has the smallest average power consumption and very small gain variation characteristic. The supply voltage of saturation point control technique is slightly larger than that of new input signal compression technique, but the structure is simpler than that of ne input signal compression technique. Therefore, the average power consumption of saturation point control technique is smaller than that of new input signal compression technique. The smallest gain variation technique is modified new level shifting technique. Using the advantages of new level shifting technique and saturation point control technique, the variation of gain can be minimized. The average power consumption of this technique, however, is higher than that of saturation point control or new input signal compression technique. One of the main advantages of new input signal compression technique is that this technique is working in the extremely low supply voltage environment and can overcome the dead zone problem of the extremely low supply voltage environment. The other techniques, new level shifting technique, saturation point control technique, and modified new level shifting technique, are working in the low supply voltage environment. Therefore, this technique has the smallest supply voltage among the proposed techniques. And new input signal compression technique has the largest CMRR because this technique employs the concept of common mode elimination technique. However, this technique has relatively large gain variation and the unity gain frequency of this technique is slightly smaller than the other three techniques. One of the main 98 disadvantages of new input signal compression technique is relatively large input referred noise. 99 Chapter 7. Conclusion Five novel rail-to-rail op-amp techniques for the portable ECG amplifier are discussed in this dissertation. The gain, bandwidth, input impedance, and CMRR of all novel techniques are considered for the ECG system and especially, for the portable electronic biomedical device, operation in the low supply voltage environment is the main consideration of this research for low power consumption. Three techniques of novel rail-to-rail op-amp techniques, the new level shifting technique, the saturation point control technique, and the modified new level shifting technique are proposed for the low supply voltage environment and can avoid the transconductance variation problem of the complementary input differential pair structure. Two techniques of novel rail-to-rail op- amp techniques, the common mode elimination technique and the new input signal compression technique, are proposed for the extremely low supply voltage environment and overcome the dead zone problem. Large transistors are employed for the input referred noise reduction for all novel techniques, except for the common mode elimination technique. One of the main drawbacks of common mode elimination technique is the reduced bandwidth problem and this noise reduction method with large transistors is not appropriate for this technique. All other novel techniques endure the reduced bandwidth because of large input transistors for the noise reduction, but still have enough bandwidth for the ECG system. 100 All novel techniques ensure constant operation over the entire rail-to-rail input common mode range. All the simulation results shows constant transconductance, constant gain, and unity gain bandwidth. Cadence SPECTRE simulator and TSMC 0.25- µm CMOS technology are used for the schematic and post layout simulations. 101 Bibliography [1] M. Wang, T. L. Mayhugh, Jr., S. H. K. Embabi, and E. Sanchez-Sinencio, “Constant-gm rail-to-rail CMOS op-amp input stage with overlapped transition region,” IEEE J. Solid-State Circuits, vol. 34, no.2, pp.148-156, Feb. 1999. [2] S. Yan, J. Hu, T. Song and E. Sánchez-Sinencio, “Constant-gm Techniques for Rail-to-Rail CMOS Amplifier Input Stages: A Comparative Study,” in Proc. IEEE International Symposium on Circuits and Systems, 2005, pp. 2571 – 2574, vol. 3, 23-26 May 2005. [3] W.-S. Wang, Z.-C. Wu, H.-Y. Huang, C.-H. Luo, “Low-Power instrumental amplifier for portable ECG,” in Proc. IEEE Circuits Syst. Int. Conf. Test. Diagnosis 2009, 2009, pp. 1–4. [4] M. J. Burke and D. T. Gleeson, “A micropower dry-electrode ECG preamplifier,” IEEE Trans. Biomed. Eng., vol. 47, no. 2, pp. 155–162, Feb. 2000. [5] R. Hogervorst, R. J. Wiegerink, P. A. L. de Jong, J. Fonderie, R. F. Wassenaar, and J. H. Huijsing, “CMOS low-voltage operational amplifiers with constant-gm rail-to-rail input stage,” IEEE Proc. ISCAS 1992, pp. 2876-2879. [6] S. Sakurai and M. Ismail, “Robust design of rail-to-rail CMOS operational amplifiers for a low power supply voltage,” IEEE Journal of Solid-State Circuits, vol. 31, no. 2, pp. 146-156, February 1996. [7] J. H. Botma, R. F. Wassenaar, and R. J. Wiegerink, “A low voltage CMOS op amp with a rail-to-rail constant-gm input stage and a class AB rail-to-rail output stage,” IEEE Proc. ISCAS 1993, vol. 2, pp. 1314-1317, May 1993. [8] R. Hogervost, J. P. Tero, R. G. H. Eschauzier and J. H. Huijsing, “A compact power-efficient 3-V CMOS rail-to-rail input/output operational amplifier for VLSI cell libraries,” IEEE Journal of Solid- State Circuits, vol. 29, no. 12, pp. 1505-1513, December 1994. [9] R. Hogervorst, S. M. Safai, and J. H. Huijsing, “A programmable 3-V CMOS rail-to-rail opamp with gain boosting for driving heavy loads,” IEEE Proc. ISCAS 1995, pp. 1544-1547. [10] J. H. Huijsing, R. Hogervorst, and K.-J. de Langen, “Low-power low-voltage VLSI operational amplifier cells,” IEEE Trans. Circuits and Systems-I, vol. 42. no.11, pp. 841-852, November 1995. [11] W. Redman-White, “A high bandwidth constant gm, and slew-rate rail-to-rail CMOS input circuit and its application to analog cell for low voltage VLSI systems,” IEEE Journal of Solid-State Circuits, vol. 32, no. 5, pp. 701-712, May 1997. [12] C. Hwang, A. Motamed, and M. Ismail, “Universal constant-gm input-stage architecture for low- voltage op amps,” IEEE Trans. Circuits and Systems-I, vol.42. no. 11, pp. 886-895, November 1995. 102 [13] C. Hwang, A. Motamed, and M. Ismail, “LV opamp with programmable rail-to-rail constant-gm,” IEEE Proc. ISCAS 1997, pp. 1988-1959. [14] J. Fonderie, M. M. Maris, E. J. Schnitger, and H. Huijsing, “1-V operational amplifier with rail-to-rail input and output ranges,” IEEE J. Solid-State Circuits, vol. 24, no. 6, pp. 1551-1559, Dec. 1989. [15] J. F. Duque-Carrillo, J. L. Aus i´n, G. Torelli, J. M. Valverde, and M. A. Dom´inguez, “1-V rail-to-rail operational amplifiers in standard CMOS technology,” IEEE J. Solid-State Circuits, vol. 35, no. 1, pp. 33-34, Jan. 2000. [16] J. M. Carrillo, J. F. Duque-Carrillo, G. Torelli, and J. L. Aus´in, “1-V quasi constant-gm input/output rail-to-rail CMOS op-amp,” in IEEE Proc. ISCAS ’03, vol. 1, May 2003, pp. 277-280. [17] G. Ferri and W. Sansen, “A rail-to-rail constant-gm low-voltage CMOS operational transcondcutor amplifier,” IEEE J. Solid-State Circuits, vol. 32, no. 10, pp. 1563-1567, Oct. 1997. [18] Stockstand T, Yoshizawa H., “A 0.9V 0.5A rail-to-rail CMOS operational amplifier”, IEEE J Solid State Circuits 2002; 37:286–292. [19] B. J. Blalock and P. E. Allen "Designing 1-volt opamps using standard digital CMOS technology", IEEE Trans. Circuits and Systems, pp.769 -780 1998. [20] R. Griffith, R. Wyne, R. Dotson, and T. Petty, “A 1-V BiCMOS rail-to-rail amplifier with n-channel depletion mode input stage,” IEEE J. Solid-State Circuits, Vol.32, pp. 2012-2022, Dec. 1997. [21] K. Khare, N. Khare, P.K. Sethiya, "Analysis of Low Voltage Rail-to- Rail CMOS Operational Amplifier Design," International Conference on Electronic Design, 2008, pp. 1-4. [22] Yutaka Yukizaki, et.al "Low-Voltage Rail-to-Rail CMOS Operational Amplifier Design" Electronics and Communications in Japan, Part 2, Vol. 89, No. 12, 2006. [23] J. Rhayem, R. Gillon, M. Tack, M. Valenza, A. Hoffmann, A. Eya, D. Rigaud, “Comments on Existing 1/f Noise Models: Spice, HSPICE and BSIM3v3 for MOSFETs in Circuit Simulators”, 32th European Solid-State Device Research Conference, ESSDERC 2002, 24-26 September 2002, Italy [24] N. Gandhi, C. Khe, D. Chung, Y. M. Chi, G. Cauwenberghs, “Properties of Dry and Non-contact Electrodes for Wearable Physiological Sensors”, IEEE Proc. Body Sensor Networks (BSN) 2011, pp. 107-112, 2011. [25] C. D. Parikh, D. Nagchoudhuri, A. Amara, “A 0.7-V Rail-to-Rail Buffer Amplifier with Double-Gate MOSFETs”, IEEE Proc. Faible Tension Faible Consommation (FTFC) 2011, pp. 19-22, 2011. 103 [26] Chia-Hao Hsu, Chi-Chun Huang, Kian Siong, Wei-Chih Hsiao, Chua-Chin Wang, "A high performance current-balancing instrumentation amplifier for ECG monitoring systems", SoC Design Conference (ISOCC), pp. 83-86, 22-24 Nov. 2009. [27] C. Nanda, J. Mukhopadhyay, D. Mandal and S. Chakrabarti, "1 V CMOS instrumentation amplifier with high DC electrode offset cancellation for ECG acquisition systems," IEEE, Students' Technology Symposium (TechSym), Kharagpur, pp. 21-25, Apr. 2010. [28] C. Nanda, J. Mukhopadhyay, D. Mandal, S. Chakrabarti, “A CMOS instrumentation amplifier with low voltage and low noise for portable ECG monitoring systems”, IEEE Proc. International Conference on Semiconductor Electronics (ICSE) 2008, pp. 54-58. 2008. [29] H. Wu and Y. P. Xu, "A Low-Voltage Low-Noise CMOS Instrumentation Amplifier for Portable Medical Monitoring Systems," IEEE-NEWCAS Conference, pp. 295-298, Jun. 2005. [30] Harb, A., Sawan, M. "New Low-Power Low-Voltage High-CMRR CMOS Instrumentation Amplifier". IEEE International Symposium on Circuits and Systems, v. 6, p. 97-100. [31] Huanzhang Huang; Karthikeyan, S.; Lee, E.K.F.; "A 1 V instrumentation amplifier" The 42nd IEEE Midwest Symposium on Circuits and Systems, Aug. 1999, Vol. 1, pp. 170-173. [32] M. Steyaert, W. Sansen, and C. Zhongyuan, “A micropower low-noise monolithic instrumentation amplifier for medical purposes”, IEEE J. Solid State Circuits, 22:1163-1168, 1987. [33] K. Koli and K.A.I. Halonen, "CMRR enhancement techniques for current-mode instrumentation amplifiers," IEEE trans. on Circuits and Systems I, vol. 47, no. 5, pp. 622-632, May 2000. [34] E. C. M. Lim , X. D. Zou , Y. J Zheng and J. Tan "Design of lowpower low-voltage biomedical amplifier for electrocardiogram signal recording", Proc. IEEE Biomedical Circuits Syst. Conf., pp.191 -194 2007. [35] N. V. Thakor and J. G. Webster, "Ground-free ECG recording with two electrodes", IEEE Trans. Biomed. Eng., vol. BME-27, pp.699 -704 1980. [36] G. Dai, P. Huang, L. Yang, and B. Wang, "A Constant gm CMOS Opamp with Rail-To-Rail Input/Output Stage," Solid-State and Integrated Circuit Technology, pp. 123-125, Nov. 2010. [37] Y. Haga and I. Kale, "CMOS buffer using complementary pair of bulk-driven super source followers," Electronics Letter, vol. 45, No. 18, 27th Aug. 2010. [38] V. Re, L. Ratti, M. Manghisoni, V. Speziali, and G. Traversi, "Survey of noise performances and scaling effects in deep submicron CMOS devices from different foundries", Proc. IEEE Nuclear Science Symp., 2004. 104 [39] W. T. Holman; J. A. Connelly, J. O. Perez, and C. D. Motchenbacher, “A Low Noise CMOS Operational Amplifier in a 1.2µm Digital Technology”, IEEE Proc. of 35th Midwest Symposium on Circuits and Systems, p.1120, Washington D.C., 1992. [40] E. K. F. Lee, E. Matei, R. Ananth, “A 0.9 V rail-to-rail constant gm amplifier for implantable biomedical applications,” IEEE Proc. International Symposium on Circuits and Systems, ISCAS 2006, pp.653-656, 2006. [41] John G. Webster, “Medical Instrumentation Application and Design,” 4th edition, John Wiley and Sons, Inc., December 2011. [42] B. Razavi, “Design of analog CMOS integrated circuits,” McGraw–Hill, 2001. [43] D. A. Johns, and K. Martin, “Analog Integrated Circuit Design”, John Wiley and Sons, Inc., 1997. [44] A. S. Sedra, and K. C. Smith, “Microelectronic Circuits”, 6th edition, Oxford University Press, Inc., 2010. [45] A. Masoom and Kh. Hadidi, "A 1.5-V constant-gm rail-to-rail input stage operational amplifier", IEEE Proceedings of the ISCAS'2006, December 10-13; 2006. pp. 632-5. [46] Jui-Lin Lai, Ting-You Lin, Cheng-Fang Tai, Yi-Te Lai, and Rong-Jian Chen, "Design a Low-Noise Operational Amplifier with Constant-gm," SICE Annual Conference 2010, August 2010. [47] E. Lee, A. Lam, and T. Li, "A 0.65V Rail-To-Rail Constant gm Opamp for Biomedical Applications," IEEE International Symposium on Circuits and Systems, pp. 2721-2724, May 2008. [48] T. W. Fischer, A. I. Karsilayan, and E. Sanchez-Sinencio, "A rail-to-rail amplifier input stage with ±0.35 % gm fluctuation," IEEE Trans. Circuits and Systems, part I, vol. 52, pp. 271-282, February 2005. [49] T. Song and S. Yan, "A robust rail-to-rail input stage with constant-gm and constant slew rate using a novel level shifter", Proc.IEEE Int. Symp. Circuits Systems, ISCAS 2007, pp.477 -480. 2007. [50] Z. Li, M. Yu and J. Ma, “A rail-to-rail I/O operational amplifier with 0.5% gm fluctuation using double p-channel differential input pairs”, IEEE Proc. VLSID 2006, Jan 2006. [51] W. Yan and H. Zimmermann, “A low-voltage fully differential constant signal behavior rail-to-rail input stage in 0.12μm CMOS”, IEEE Proc. NORCHP 2007, pp.1-4. Nov. 2007. [52] W. Yan and H. Zimmermann, “Fully Differential Rail-to-rail Input Opamp With Novel Constant- transconductance Control In 120nm CMOS Technology”, IEEE Proc. MIXDES 2006, pp.294-298. June 2006. 105 [53] J. M. Carrillo, J. F. Duque-Carrillo, G. Torelli and J. L. Ausin, “Constant-gm constant-slew-rate high- bandwidth low-voltage rail-to-rail CMOS input stage for VLSI cell libraries”, IEEE Proc. International Symposium on Circuits and Systems, ISCAS 2003, Vol. 1, pp.I.165-I.168, May 2003. [54] Wang Xichuan, Deng Huan and Zhang Ting, “A Rail-To-Rail Op-Amp with Constant Gm Using Current Switches”, IEEE Proc. International Symposium on High Density Packaging and Microsystem Integration, HDP 2007, pp.1-3. June 2007. [55] A. Danchiv, M. Bodea and C. Dan, “Total transconductance optimization for a rail to rail amplifier”, IEEE Proc. 11 th International Conference on Optimization of Electrical Electronic Equipment, OPTIM 2008, pp.25-31. May 2008. [56] F. You, S.H.K. Embabi, and E. S nchez-Sinencio, "Low-voltage class AB buffers with quiescent current control", IEEE Journal of Solid-State Circuits, vol 33, no 6, pp. 915-920, June 1998. [57] J. F. Duque-Carrillo, J. M. Carrillo, J. L. Ausin, and E. S nchez-Sinencio, "Robust and universal constant-gm circuit technique", Electron. Lett., vol. 38, no. 9, pp.396 -397, 2002. [58] T. W. Fischer and A. I. Karsilayan, "Rail-to-rail amplifier input stage with constant gm and common- mode elimination", Electron. Lett., vol. 38, no. 24, pp.1491 -1492, 2002. [59] J. Ramirez-Angulo, R.G. Carvajal, J. Tombs, and A.Torralba, "Low-voltage CMOS Op-amp with rail- to-rail input and output signal swing for continuous-time signal processing using multiple-input floating-gate transistors," IEEE Transactions on Circuits and Systems II, vol. 48, no. 1, pp. 110-116, Jan. 2001. [60] J. Feng, N. Yan, and H. Min, “A low-power low-noise amplifier for EEG/ECG signal recording applications”, IEEE Proc. ASICON 2011, pp.145-148, Oct. 2011. [61] S. Yan and E. S nchez-Sinencio, "A programmable rail-to-rail constant-gm input structure for LV amplifier", Proc. IEEE ISCAS'00, vol. 5, pp.645 -648, 2000. [62] M. D. Pardoen and M. G. Degrauwe, “A rail-to-rail input/output CMOS power amplifier,” IEEE J. Solid-State Circuits, vol. SC-25. pp. 50 1-504. Dec. 1990. [63] M. A. G. Lorenzo, A. A. S. Manzano, M. T. A. Gusad, J. R. E. Hizon, M. D. Rosales, “Design and Implementaion of CMOS Rail-to-Rail Operational Amplifiers,” IEEE, Communications and Information Technologies, ISCIT ’07, pp. 61-66, Oct. 2007. [64] S. V. Gopalaiah and A. P. Shivaprasad, “Low Voltage CMOS op-amp with Rail-to-Rail Input/Output Swing,” IEEE Proc. International Workshop on Electronic Design, Test and Applications, DELTA’04, pp.349-354. Jan. 2004. 106 [65] J. H. Huijsing and D. Linebarger, “Low-voltage operational amplifier with rail-to-rail input and output ranges,” IEEE J. Solid-State Circuits. vol. SC-20, pp. 1144-1150, Dec. 1985. [66] C. W. Lu and C. M. Hsiao, “0.9 V rail-to-rail constant gm CMOS amplifier input stage”, Electron. Lett., Vol. 45, No. 23, pp.1145-1146, 2009. [67] J. M. Carrillo, G. Torelli, R. P rez-Aloe, and J. F. Duque-Carrillo, "1-V Rail-to-Rail CMOS OpAmp with Improved Bulk-Driven Input Stage," IEEE J. Solid-State Circuits, vol. 42, pp. 508-517, March 2007. [68] H. Chow and P. Weng, "A Low Voltage Rail-To-Rail Opamp Design for Biomedical Signal Filtering Applications," IEEE International Symposium on Electronic Design, pp. 232-235, Jan. 2008. [69] M. F. Li, U. Dasgupta, X. W. Zhang, and Y. C. Lim, "A low-voltage CMOS OTA with rail-to-rail differential input range," IEEE Trans. Circuits Syst. I, vol.47, No.1, pp. 1-8, January 2000. [70] M. K. Hati, and T. K. Bhattacharyya, “A power efficient and constant-gm 1.8 V CMOS operational transconductance amplifier with rail-to-rail input and output ranges for charge pump in phase-locked loop”, IEEE Proc. International Conference on Devices, Circuits and Systems, ICDCS 2012, pp. 38-43, Mar. 2012. [71] C. Guo, S. Zhu, J. Hu, J. Zou, H. Sun, and X. Lv, “A low voltage CMOS rail-to-rail operational amplifier based on flipped differential pairs”, IEEE Proc. MAPE 2011, pp. 217-220, Nov. 2011. [72] R. Hogervorst, J. P. Tero, and J. H. Huijsing, "Compact CMOS constant-gm rail-to-rail input stages with gm-control by electronic Zener diode", European Solid-State Circuits Conference, 1995. [73] Z. Wu, F. Rui, Z. Zhi-Yong, and C. Wei-Dong, "Design of a Rail-To-Rail Constant-gm CMOS Operational Amplifier," 2009 WRI World Congress on Computer Science and Information Engineering, Vol. 6, pp.198-201, April 2009. [74] N. Tadic, M. Banjevic, F. Schloegl, and H. Zimmermann, “Input adapter based BiCMOS operational amplifier with rail-to-rail capability”, IEEE Proc. International Conference on Microelectronics, ICMEL 2008, pp. 403-406, May 2008. [75] D. J. Comer and D. T. Comer "Using the Weak Inversion Region to Optimize Input Stage Design of CMOS Op Amps", IEEE Trans. Circuits Syst. II, Exp. Briefs, vol. 51, no. 1, pp.8 -14, 2004. 107 Appendix Low Power Weak Inversion Op-Amps In [75], op-amps operating in the weak inversion region and strong inversion regions are compared and explained. Operating transistors in weak inversion has several advantages such as higher voltage gain, low power consumption, decreased distortion, higher output resistance, and so on. All five novel techniques of this dissertation are operated in strong inversion region and for the comparison of weak inversion and strong inversion regions operation, the new level shifting technique is simulated in weak inversion region as an example. As mentioned in [75], of weak inversion region operation is below 20mV while that of strong inversion region operation is over 80 ~ 220mV. ( | | ) The bias currents of the op-amp architecture used in the new level shifting technique were adjusted so the amplifies operated in the weak inversion region. The currents of complementary input differential pairs and folded cascode current summing stage were originally all 10µA and was about 250mV. For weak inversion region operation, the currents of complementary input differential pairs and folded cascode current summing stage were reduced from 10µA to 3.3µA. Because of reduced drain current, | | of input stage and folded cascode stage devices were smaller than that of strong inversion region operation and as a result, of devices reduced to about 10mV. The simulation results 108 comparisons are given in Table A. 1. Because of the reduced currents, the power consumption is decreased significantly. Notice that overall the specifications of the reduced power operation are very close to that of the higher power case, but some increased gain variation versus common mode input voltage is observed. Slew rate, which was not specified or simulated in this thesis, is also lower. Strong Inversion Region Weak Inversion Region Supply Voltage 1.6V 1.6V ICMR Rail-to-Rail Rail-to-Rail ≈ 250mV ≈ 10mV Gm Variation ±8.66% ±9.78% Avg. Gain 77.08dB 81.14dB Gain Variation ±1.3dB ±1.34dB Unity Gain Freq. 1.25MHz 1.3MHz Phase Margin 58.9º 57.1dº CMRR ≥ 73.29dB ≥ 83.66dB Current Source 10µA 3.3µA Avg. Power Consumption (@150Hz) 79.14µW 35.7µW Table A. 1 Simulation Results Comparisons of Strong and Weak Inversion Regions Operation