Cerron Grande Project

Loading...
Thumbnail Image

View/Download File

Persistent link to this item

Statistics
View Statistics

Journal Title

Journal ISSN

Volume Title

Title

Cerron Grande Project

Alternative title

Published Date

1973-01

Publisher

St. Anthony Falls Hydraulic Laboratory

Type

Report

Abstract

This report describes the results of a hydraulic model test for the Cerron Grande hydroelectric power project. A 1:100 undistorted scale model including the spillway, the power intake and outlet, the headwater approach channel, the spillway exit channel, and a portion of the existing river downstream of the proposed dam site was constructed and tested. All major features of the model performed satisfactorily. The deflector at the downstream end of the spillway was very effective and operated satisfactorily over the entire range of discharges tested. Concentrated vortices were found at the spillway gates when the four gates were not open equally.

Keywords

Description

Related to

Replaces

License

Collections

Series/Report Number

Saint Anthony Falls Laboratory Project Reports
139

Funding information

Harza Engineering Company; Hydroelectric Power Commission of the Lempa River, El Salvador, Central America

Isbn identifier

Doi identifier

Previously Published Citation

Other identifiers

Suggested citation

Song, Charles. (1973). Cerron Grande Project. Retrieved from the University Digital Conservancy, https://hdl.handle.net/11299/114849.

Content distributed via the University Digital Conservancy may be subject to additional license and use restrictions applied by the depositor. By using these files, users agree to the Terms of Use. Materials in the UDC may contain content that is disturbing and/or harmful. For more information, please see our statement on harmful content in digital repositories.