University of Minnesota Digital Conservancy >
       University of Minnesota - Twin Cities >
          Dissertations and Theses >
             Dissertations >

Please use this permanent URL to cite or link to this item: http://purl.umn.edu/113204

Title: Water temperature as a tracer in karst aquifers.
Authors: Luhmann, Andrew James
Keywords: Aquifer
Heat transport
Hydrograph
Karst
Spring
Water temperature
Geology
Issue Date: Jul-2011
Abstract: Water temperature at springs generally provides useful information concerning aquifer geometry and recharge. Temperature monitoring at 25 springs and cave streams in southeastern Minnesota has shown four distinct thermal patterns that can be interpreted in terms of heat exchange effectiveness along a flow path and the nature of recharge. The patterns provide information about the size of the flow path, recharge type and duration, and aquifer depth. Water temperature is generally an interactive tracer, where heat exchange rapidly occurs when water and aquifer rock are at different temperatures. In a multi-tracer experiment at Freiheit Spring, MN, uranine, chloride, and δD breakthrough curves were essentially identical and conservative. In contrast, the water temperature interacted with the aquifer as it moved along the flow path, producing a damped, lagged thermal signal at the spring. However, both the conservative and nonconservative tracers provide useful geometrical information. By summing discharge between the initial increase in stage produced by a pressure pulse and the chloride peak, the conduit volume is estimated as 51 m<super>3</super>. Using a heat transport simulation to reproduce the modified thermal signal requires a planar flow path with a hydraulic diameter of 7 cm. Both methods together suggest a bedding plane flow path that is 3.5 cm high by 10 m wide, in agreement with the observed spring geometry. The different tracers provide complementary information and stronger constraints on flow path geometry than could be obtained using a single tracer. Finally, numerical simulations were run to determine variables controlling thermal retardation in karst conduits. The lag of a thermal peak in the water is proportional to a conduit's length; is proportional to the square root of recharge duration, rock thermal conductivity, rock specific heat, and rock density; and is inversely proportional to a conduit's hydraulic diameter, velocity, water specific heat, and water density. These individual relationships were then combined to form one collective function, which, when plotted against thermal peak lag produced a line in log-log space. The relationship between the thermal peak lag and the combined function potentially enables estimates of conduit geometry using thermal peak lag data.
Description: University of Minnesota Ph.D. dissertation. July 2011. Major:Geology. Advisor: E. Calvin Alexander, Jr. 1 computer file (PDF); xi, 164 pages, appendices A-F + 23 supplemental files (TXT; tab-delimited numerical data)
Permanent URL: http://purl.umn.edu/113204
Appears in Collections:Dissertations

Files in This Item:

File Description SizeFormat
MN23X0141_091203-101110_TCL.txt695KbTextView/Open
MN23X0117_080626-090826_TCLP.txt483KbTextView/Open
MN23A0098_080812-081031_TC.txt87KbTextView/Open
MN85A0312_080812-090714_TC.txt363KbTextView/Open
MN85A0255_Emanation_080812-101220_TCL.txt1095KbTextView/Open
MN23X0145_110203-110502_TCL.txt122KbTextView/Open
MN85A0005_081031-091024_TCV.txt500KbTextView/Open
MN23X0016_080313-110316_TCLP.txt1628KbTextView/Open
MN23A0041_100825-100928_TCL.txt576KbTextView/Open
MN23X0143_MN23X0144_100501-110316_TI.txt591KbTextView/Open
MN23A0033_090904-100819_TCL.txt479KbTextView/Open
MN23A0887_100527-100825_TI.txt204KbTextView/Open
MN23X0142_100501-110502_TI.txt795KbTextView/Open
MN23A0001_100501-110203_TI.txt616KbTextView/Open
MN85A0266_080812-100505_TCL.txt868KbTextView/Open
MN85A0255_Boils_100106-101110_TCL.txt419KbTextView/Open
MN23A0041_081031-110502_TCLD.txt2081KbTextView/Open
MN23X0146_100527-101020_TI.txt320KbTextView/Open
MN23A0034_100928-110502_TCL.txt292KbTextView/Open
Luhmann_umn_0130E_12126.pdf14119KbPDFView/Open
MN23A0001_110203-110502_TCL.txt121KbTextView/Open
MN23A0875_100501-110502_TI.txt780KbTextView/Open
MN23X0131_100616-110502_TCL.txt393KbTextView/Open
MN85A0053_080812-081031_TC.txt87KbTextView/Open

Items in the Digital Conservancy are protected by copyright, with all rights reserved, unless otherwise indicated.