Skip to main content
Performance Assessment of Modified ecoStorm Hydrodynamic Separator
Mohseni, Omid; Fyten, Andrew (St. Anthony Falls Laboratory, 2008)
 

Title 
Performance Assessment of Modified ecoStorm Hydrodynamic Separator

Issue Date
2008-06

Publisher
St. Anthony Falls Laboratory

Type
Report

Abstract
Royal Environmental Systems, Inc. requested a series of tests to be conducted on their Model 3 ecoStorm hydrodynamic separator to determine its efficiency in removing suspended solids as well as its scouring potential under high flow conditions. A Model 3 ecoStorm was brought into St. Anthony Falls Laboratory (SAFL) and set up for testing. After conducting a series of tests, Royal Environmental Systems, Inc. modified the Model 3 ecoStorm. The report herein is a summary of the tests conducted at SAFL to determine the removal efficiency and the scouring potential of the Modified Model 3 ecoStorm

Appears in Collection(s)

Series/Report Number
St. Anthony Falls Laboratory Project Reports
495B

Suggested Citation
Mohseni, Omid; Fyten, Andrew. (2008). Performance Assessment of Modified ecoStorm Hydrodynamic Separator. St. Anthony Falls Laboratory. Retrieved from the University of Minnesota Digital Conservancy, http://purl.umn.edu/132243.